Literature DB >> 21919433

Clinical significance of B-scan averaging with SD-OCT.

Rajeev R Pappuru1, Cesar Briceno, Yanling Ouyang, Alexander C Walsh, Srinivas R Sadda.   

Abstract

Averaging multiple scans is a potential advantage of optical coherence tomography. The authors evaluate the qualitative benefits of B-scan averaging on the visualization of outer retinal structures. A retrospective analysis was performed on Cirrus OCT (Carl Zeiss Meditec, Dublin, CA) B-scans from 1 eye of 35 patients referred to the imaging unit who underwent three types of scan acquisitions: no averaging, 4× averaging, and 20× averaging. Masked assessment of quality was made using a qualitative scale of 0 (worst) to 3 according to the ability to identify structure, brightness, and continuity. Quality scores consistently improved with 4× averaging, but improved only slightly further with 20×. Averaging appeared to have a statistically significant beneficial effect for the assessment of the external limiting membrane and outer nuclear layer (P < .05), with no significant benefit for visualization of the retinal pigment epithelium and inner segment/outer segment junction. The benefits of oversampling or averaging B-scans for visualizing outer retinal substructures are apparent even when averaging relatively few frames. These findings may be helpful when designing acquisition protocols in clinical trials and clinical practice. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2011        PMID: 21919433     DOI: 10.3928/15428877-20110908-02

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging        ISSN: 1542-8877


  7 in total

1.  Optical Coherence Tomography (OCT) Device Independent Intraretinal Layer Segmentation.

Authors:  Alexander Ehnes; Yaroslava Wenner; Christoph Friedburg; Markus N Preising; Wadim Bowl; Walter Sekundo; Erdmuthe Meyer Zu Bexten; Knut Stieger; Birgit Lorenz
Journal:  Transl Vis Sci Technol       Date:  2014-02-11       Impact factor: 3.283

2.  Objective determination of optimal number of spectral-domain optical coherence tomographic images of retina to average.

Authors:  Makoto Shirasawa; Taiji Sakamoto; Hiroto Terasaki; Takehiro Yamashita; Eisuke Uchino; Shozo Sonoda
Journal:  PLoS One       Date:  2014-10-22       Impact factor: 3.240

3.  Impact of B-Scan Averaging on Spectralis Optical Coherence Tomography Image Quality before and after Cataract Surgery.

Authors:  Dominika Podkowinski; Ehsan Sharian Varnousfaderani; Christian Simader; Hrvoje Bogunovic; Ana-Maria Philip; Bianca S Gerendas; Ursula Schmidt-Erfurth; Sebastian M Waldstein
Journal:  J Ophthalmol       Date:  2017-05-23       Impact factor: 1.909

4.  Comparison of choroidal thickness using swept-source and spectral-domain optical coherence tomography in normal Indian eyes.

Authors:  Siddharth Narendran; George Manayath; Narendran Venkatapathy
Journal:  Oman J Ophthalmol       Date:  2018 Jan-Apr

5.  Development and quantitative assessment of deep learning-based image enhancement for optical coherence tomography.

Authors:  Xinyu Zhao; Bin Lv; Lihui Meng; Xia Zhou; Dongyue Wang; Wenfei Zhang; Erqian Wang; Chuanfeng Lv; Guotong Xie; Youxin Chen
Journal:  BMC Ophthalmol       Date:  2022-03-26       Impact factor: 2.209

6.  Post-processing sets of tilted CT volumes as a method for metal artifact reduction.

Authors:  Hendrik Ballhausen; Michael Reiner; Ute Ganswindt; Claus Belka; Matthias Söhn
Journal:  Radiat Oncol       Date:  2014-05-15       Impact factor: 3.481

7.  The correlation between optical coherence tomography retinal shape irregularity and axial length.

Authors:  Stewart Lake; Murk Bottema; Keryn Williams; Karen Reynolds
Journal:  PLoS One       Date:  2019-12-30       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.