Literature DB >> 21919201

Automatic filtration and filter flush for robust online solid-phase extraction liquid chromatography.

Kristin O Svendsen1, Hanne R Larsen, Siri A Pedersen, Ida Brenna, Elsa Lundanes, Steven R Wilson.   

Abstract

Online solid-phase extraction-liquid chromatography (SPE-LC) with microbore or capillary columns was significantly improved regarding robustness, as an easily installed automatic filtration and filter flushing (AFFL) procedure was added to avoid system clogging. Specifically, an injected sample is passed through a union containing a stainless steel filter prior to SPE trapping. The filter stops any particulate matter from reaching the SPE. When the SPE is subsequently connected to the LC column by column switching, a separate pump backflushes the filter-union, removing the particulate matter off the filter after each injection. This feature greatly reduced backpressure buildup over the entire system.
Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21919201     DOI: 10.1002/jssc.201100553

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  4 in total

1.  Highly automated nano-LC/MS-based approach for thousand cell-scale quantification of side chain-hydroxylated oxysterols.

Authors:  Hanne Roberg-Larsen; Kaja Lund; Tore Vehus; Nina Solberg; Caroline Vesterdal; Dorna Misaghian; Petter Angell Olsen; Stefan Krauss; Steven Ray Wilson; Elsa Lundanes
Journal:  J Lipid Res       Date:  2014-05-02       Impact factor: 5.922

2.  Immunocapture sample clean-up in determination of low abundant protein biomarkers - a feasibility study of peptide capture by anti-protein antibodies.

Authors:  Maren C S Levernæs; Bassem Farhat; Inger Oulie; Sazan S Abdullah; Elisabeth Paus; Léon Reubsaet; Trine G Halvorsen
Journal:  RSC Adv       Date:  2019-10-29       Impact factor: 4.036

3.  Liquid chromatography-mass spectrometry platform for both small neurotransmitters and neuropeptides in blood, with automatic and robust solid phase extraction.

Authors:  Elin Johnsen; Siri Leknes; Steven Ray Wilson; Elsa Lundanes
Journal:  Sci Rep       Date:  2015-03-20       Impact factor: 4.379

4.  Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring.

Authors:  Hanne Roberg-Larsen; Silvija Abele; Deniz Demir; Diana Dzabijeva; Sunniva F Amundsen; Steven R Wilson; Vadims Bartkevics; Elsa Lundanes
Journal:  Front Chem       Date:  2017-08-28       Impact factor: 5.221

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.