Literature DB >> 21918165

Lack of effectiveness of the pulmonary artery catheter in cardiac surgery.

Nanette M Schwann1, Zak Hillel, Andreas Hoeft, Paul Barash, Patrick Möhnle, Yinghui Miao, Dennis T Mangano.   

Abstract

BACKGROUND: The pulmonary artery catheter (PAC) continues to be used for monitoring of hemodynamics in patients undergoing coronary artery bypass graft (CABG) surgery despite concerns raised in other settings regarding both effectiveness and safety. Given the relative paucity of data regarding its use in CABG patients, and given entrenched practice patterns, we assessed the impact of PAC use on fatal and nonfatal CABG outcomes as practiced at a diverse set of medical centers.
METHODS: Using a formal prospective observational study design, 5065 CABG patients from 70 centers were enrolled between November 1996 and June 2000 using a systemic sampling protocol. Propensity score matched-pair analysis was used to adjust for differences in likelihood of PAC insertion. The predefined composite endpoint was the occurrence of any of the following: death (any cause), cardiac dysfunction (myocardial infarction or congestive heart failure), cerebral dysfunction (stroke or encephalopathy), renal dysfunction (dysfunction or failure), or pulmonary dysfunction (acute respiratory distress syndrome). Secondary variables included treatment indices (inotrope use, fluid administration), duration of postoperative intubation, and intensive care unit length of stay. After categorization based on PAC and transesophageal echocardiography use (both, neither, PAC only, transesophageal echocardiography only), we performed the primary analysis contrasting PAC only and neither (total, 3321 patients), from which propensity paring yielded 1273 matched pairs.
RESULTS: The primary endpoint occurred in 271 PAC patients versus 196 without PAC (21.3% vs.15.4%; adjusted odds ratio [AOR], 1.68; 95% confidence interval [CI], 1.24 to 2.26; P<0.001). The PAC group had an increased risk of all-cause mortality, 3.5% vs 1.7% (AOR, 2.08; 95% CI, 1.11 to 3.88; P=0.02) and an increased risk of cardiac (AOR, 1.58; 95% CI, 1.14 to 2.20; P=0.007), cerebral (AOR, 2.02; 95% CI, 1.08 to 3.77; P=0.03) and renal (AOR, 2.47; 95% CI, 1.68 to 3.62; P<0.001) morbid outcomes. PAC patients received inotropic drugs more frequently (57.8% vs 50.0%; P<0.001), had a larger positive IV fluid balance after surgery (3220 mL vs 3022 mL; P=0.003), and experienced longer time to tracheal extubation (15.40 hours [11.28/20.80] versus 13.18 hours [9.58/19.33], median plus Q1/Q3 interquartile range; P<0.0001). Use of PAC was also associated with prolonged intensive care unit stay (14.5% vs 10.1%; AOR, 1.55; 95% CI, 1.06 to 2.27; P=0.02).
CONCLUSIONS: Use of a PAC during CABG surgery was associated with increased mortality and a higher risk of severe end-organ complications in this propensity-matched observational study. A randomized controlled trial with defined hemodynamic goals would be ideal to either confirm or refute our findings.

Entities:  

Mesh:

Year:  2011        PMID: 21918165     DOI: 10.1213/ANE.0b013e31822c94a8

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  17 in total

Review 1.  The pulmonary artery catheter.

Authors:  Jean-Louis Vincent
Journal:  J Clin Monit Comput       Date:  2012-08-12       Impact factor: 2.502

Review 2.  Minimally invasive or noninvasive cardiac output measurement: an update.

Authors:  Lisa Sangkum; Geoffrey L Liu; Ling Yu; Hong Yan; Alan D Kaye; Henry Liu
Journal:  J Anesth       Date:  2016-03-09       Impact factor: 2.078

Review 3.  Goal-directed therapy in the operating room: is there any benefit?

Authors:  Jason B O'Neal; Andrew D Shaw
Journal:  Curr Opin Anaesthesiol       Date:  2016-02       Impact factor: 2.706

4.  Central venous pressure after coronary artery bypass surgery: does it predict postoperative mortality or renal failure?

Authors:  Judson B Williams; Eric D Peterson; Daniel Wojdyla; Ralf Harskamp; Kevin W Southerland; T Bruce Ferguson; Peter K Smith; Carmelo A Milano; Renato D Lopes
Journal:  J Crit Care       Date:  2014-06-09       Impact factor: 3.425

5.  Vasoactive-inotropic score as a predictor of morbidity and mortality in adults after cardiac surgery with cardiopulmonary bypass.

Authors:  Yumiko Yamazaki; Koji Oba; Yoshiro Matsui; Yuji Morimoto
Journal:  J Anesth       Date:  2018-01-13       Impact factor: 2.078

6.  Pulmonary Artery Catheter (PAC) Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM): An Ovine Cardiac Output Validation.

Authors:  Robert A Phillips; Sally G Hood; Beverley M Jacobson; Malcolm J West; Li Wan; Clive N May
Journal:  Crit Care Res Pract       Date:  2012-05-09

7.  Correlation of cardiac output measured by non-invasive continuous cardiac output monitoring (NICOM) and thermodilution in patients undergoing off-pump coronary artery bypass surgery.

Authors:  Hoiyin Cheung; Quan Dong; Rong Dong; Buwei Yu
Journal:  J Anesth       Date:  2014-11-08       Impact factor: 2.078

8.  Use of pulmonary artery catheter in coronary artery bypass graft. Costs and long-term outcomes.

Authors:  Fei Xu; Qian Wang; Heng Zhang; Sipeng Chen; Hushan Ao
Journal:  PLoS One       Date:  2015-02-17       Impact factor: 3.240

9.  Risk factors of postcardiotomy ventricular dysfunction in moderate-to-high risk patients undergoing open-heart surgery.

Authors:  Christoph Ellenberger; Tornike Sologashvili; Mustafa Cikirikcioglu; Gabriel Verdon; John Diaper; Tiziano Cassina; Marc Licker
Journal:  Ann Card Anaesth       Date:  2017 Jul-Sep

Review 10.  Stroke Volume Monitoring: Novel Continuous Wave Doppler Parameters, Algorithms and Advanced Noninvasive Haemodynamic Concepts.

Authors:  R A Phillips; B E Smith; V M Madigan
Journal:  Curr Anesthesiol Rep       Date:  2017-11-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.