Literature DB >> 21917783

Myocardial uptake of 7'-(Z)-[(123)I]iodorotenone during vasodilator stress in dogs with critical coronary stenoses.

Alexis Broisat1, Mirta Ruiz, Norman C Goodman, Stephen M Hanrahan, Bryan W Reutter, Kathleen M Brennan, Mustafa Janabi, Saul Schaefer, Denny D Watson, George A Beller, Henry F VanBrocklin, David K Glover.   

Abstract

BACKGROUND: There is a well-recognized need for a new generation of single photon emission computed tomography (SPECT) perfusion tracers with improved myocardial extraction over a wide flow range. Radiotracers that target complex I of the mitochondrial electron transport chain have been proposed as a new class of myocardial perfusion imaging agents. 7-(Z)-[(125)I]iodorotenone ((125)I-ZIROT) has demonstrated superior myocardial extraction and retention characteristics in rats and in isolated perfused rabbit hearts. We sought to fully characterize the biodistribution and myocardial extraction versus flow relationship of (123)I-ZIROT in an intact large-animal model. METHODS AND
RESULTS: The (123)I-ZIROT was administered during adenosine A(2A) agonist-induced hyperemia in 5 anesthetized dogs with critical left anterior descending (LAD) stenoses. When left circumflex (LCx) flow was maximal, (123)I-ZIROT and microspheres were coinjected and the dogs were euthanized 5 minutes later. (123)I-ZIROT biodistribution was evaluated in 2 additional dogs by in vivo planar imaging. At (123)I-ZIROT injection, transmural LAD flow was unchanged from baseline (mean±SEM, 0.90±0.22 versus 0.87±0.11 mL/[min · g]; P=0.92), whereas LCx zone flow increased significantly (mean±SEM, 3.25±0.51 versus 1.00±0.17 mL/[min · g]; P<0.05). Myocardial (123)I-ZIROT extraction tracked regional myocardial flow better than either thallium-201 or (99m)Tc-sestamibi from previous studies using a similar model. Furthermore, the (123)I-ZIROT LAD/LCx activity ratios by ex vivo imaging or well counting (mean±SEM, 0.42±0.08 and 0.45±0.1, respectively) only slightly underestimated the LAD/LCx microsphere flow ratio (0.32±0.09).
CONCLUSIONS: The ability of (123)I-ZIROT to more linearly track blood flow over a wide range makes it a promising new SPECT myocardial perfusion imaging agent with potential for improved coronary artery disease detection and better quantitative estimation of the severity of flow impairment.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21917783      PMCID: PMC3587960          DOI: 10.1161/CIRCIMAGING.110.961763

Source DB:  PubMed          Journal:  Circ Cardiovasc Imaging        ISSN: 1941-9651            Impact factor:   7.792


  41 in total

1.  MIRDOSE: personal computer software for internal dose assessment in nuclear medicine.

Authors:  M G Stabin
Journal:  J Nucl Med       Date:  1996-03       Impact factor: 10.057

2.  Technetium-99m-tetrofosmin, technetium-99m-MIBI and thallium-201 uptake in rat myocardial cells.

Authors:  A S Arbab; K Koizumi; K Toyama; T Arai; T Araki
Journal:  J Nucl Med       Date:  1998-02       Impact factor: 10.057

3.  Kinetic analysis of 18F-fluorodihydrorotenone as a deposited myocardial flow tracer: comparison to 201Tl.

Authors:  Robert C Marshall; Patricia Powers-Risius; Bryan W Reutter; James P O'Neil; Michael La Belle; Ronald H Huesman; Henry F VanBrocklin
Journal:  J Nucl Med       Date:  2004-11       Impact factor: 10.057

4.  Myocardial 99mTc-tetrofosmin uptake during adenosine-induced vasodilatation with either a critical or mild coronary stenosis: comparison with 201Tl and regional myocardial blood flow.

Authors:  D K Glover; M Ruiz; J Y Yang; W H Smith; D D Watson; G A Beller
Journal:  Circulation       Date:  1997-10-07       Impact factor: 29.690

5.  Mechanism of uptake of technetium-tetrofosmin. II: Uptake into isolated adult rat heart mitochondria.

Authors:  A Younès; J A Songadele; J Maublant; E Platts; R Pickett; A Veyre
Journal:  J Nucl Cardiol       Date:  1995 Jul-Aug       Impact factor: 5.952

6.  Myocardial uptake of (99m)Tc-N-NOET and (201)Tl during dobutamine infusion. Comparison with adenosine stress.

Authors:  D A Calnon; M Ruiz; G Vanzetto; D D Watson; G A Beller; D K Glover
Journal:  Circulation       Date:  1999-10-12       Impact factor: 29.690

7.  Synthesis and biological evaluation in mice of (2-[11C]methoxy)-6',7'-dihydrorotenol, a second generation rotenoid for marking mitochondrial complex I activity.

Authors:  A Charalambous; L Tluczek; K A Frey; D S Higgins; T J Greenamyre; M R Kilbourn
Journal:  Nucl Med Biol       Date:  1995-05       Impact factor: 2.408

8.  Mitochondrial localization and characterization of 99Tc-SESTAMIBI in heart cells by electron probe X-ray microanalysis and 99Tc-NMR spectroscopy.

Authors:  D P Piwnica-Worms; J F Kronauge; A LeFurgey; M Backus; D Hockett; P Ingram; M Lieberman; B L Holman; A G Jones; A Davison
Journal:  Magn Reson Imaging       Date:  1994       Impact factor: 2.546

9.  Myocardial kinetics of TcN-NOET: a neutral lipophilic complex tracer of regional myocardial blood flow.

Authors:  C Ghezzi; D Fagret; C C Arvieux; J P Mathieu; R Bontron; R Pasqualini; J de Leiris; M Comet
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

10.  Comparison between 201Tl and 99mTc sestamibi uptake during adenosine-induced vasodilation as a function of coronary stenosis severity.

Authors:  D K Glover; M Ruiz; N C Edwards; M Cunningham; J P Simanis; W H Smith; D D Watson; G A Beller
Journal:  Circulation       Date:  1995-02-01       Impact factor: 29.690

View more
  6 in total

1.  Novel SPECT perfusion imaging agents with improved myocardial or liver kinetics: experimental studies and the need for clinical evaluation.

Authors:  Laurent M Riou; Alexis Broisat
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

Review 2.  Quantitative Assessment of Coronary Microvascular Function: Dynamic Single-Photon Emission Computed Tomography, Positron Emission Tomography, Ultrasound, Computed Tomography, and Magnetic Resonance Imaging.

Authors:  Attila Feher; Albert J Sinusas
Journal:  Circ Cardiovasc Imaging       Date:  2017-08       Impact factor: 7.792

3.  Underestimation of coronary artery disease with SPECT perfusion imaging.

Authors:  George A Beller
Journal:  J Nucl Cardiol       Date:  2008 Mar-Apr       Impact factor: 3.872

Review 4.  New SPECT and PET radiopharmaceuticals for imaging cardiovascular disease.

Authors:  Oyebola O Sogbein; Matthieu Pelletier-Galarneau; Thomas H Schindler; Lihui Wei; R Glenn Wells; Terrence D Ruddy
Journal:  Biomed Res Int       Date:  2014-05-11       Impact factor: 3.411

Review 5.  Mitochondrial-Targeted Molecular Imaging in Cardiac Disease.

Authors:  Jinhui Li; Jing Lu; You Zhou
Journal:  Biomed Res Int       Date:  2017-05-30       Impact factor: 3.411

6.  Biodistribution and radiodosimetry of a novel myocardial perfusion tracer 123I-CMICE-013 in healthy rats.

Authors:  Yin Duan; Julia Lockwood; Lihui Wei; Chad Hunter; Karen Soueidan; Corinne Bensimon; Pasan Fernando; R Glenn Wells; Terrence D Ruddy
Journal:  EJNMMI Res       Date:  2014-03-13       Impact factor: 3.138

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.