Literature DB >> 21916560

A custom-made guide for femoral component positioning in hip resurfacing arthroplasty: development and validation study.

E Audenaert1, K De Smedt, F Gelaude, T Clijmans, C Pattyn, B Geebelen.   

Abstract

In the field of hip resurfacing arthroplasty, accurate femoral component placement is important to achieving a positive outcome and implant survival in both the short and long term. In this study, femoral component placement was defined preoperatively using virtual computed tomography-based surgical simulation of a classical posterior surgical approach. Custom-made surgical drill guides were produced to reproduce the surgical plan in the operating room. We first developed a custom-made guide for guide-wire placement to position the femoral resurfacing component. Then, to assess the accuracy in vivo, the custom-made guide was evaluated in five patients with normal anatomy. The first hypothesis of this patient study was that the use of custom-made neck guides would allow for an average accuracy within the range of ± 4° for the drill path and ± 4 mm for the entry point of the guide-wire. A second hypothesis was that three-dimensional preoperative planning would enable the prediction of an implant size differing by a maximum of one size from the size eventually implanted. The presented hip resurfacing guide performed well in terms of fit, stability and accuracy. The in vivo accuracy study revealed an accuracy of 4.05 ± 1.84° for the drill path and 2.73 ± 1.97 mm for the entry point of the guide-wire. The predicted component sizes and the implanted component sizes differed maximally by one size, confirming our hypothesis. We conclude that these preliminary data are promising, but require further validation in a full clinical setting in larger patient groups.

Entities:  

Mesh:

Year:  2011        PMID: 21916560     DOI: 10.3109/10929088.2011.613951

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  9 in total

1.  Application of computer-aided design and 3D-printed navigation template in Locking Compression Pediatric Hip PlateΤΜ placement for pediatric hip disease.

Authors:  Pengfei Zheng; Qingqiang Yao; Peng Xu; Liming Wang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-11       Impact factor: 2.924

Review 2.  Regenerative orthopaedics: in vitro, in vivo...in silico.

Authors:  Liesbet Geris
Journal:  Int Orthop       Date:  2014-07-02       Impact factor: 3.075

3.  CUSTOMIZED GUIDE FOR FEMORAL COMPONENT POSITIONING IN HIP RESURFACING ARTHROPLASTY.

Authors:  Chaturong Pornrattanamaneewong; Rapeepat Narkbunnam; Keerati Chareancholvanich
Journal:  Acta Ortop Bras       Date:  2017 Mar-Apr       Impact factor: 0.513

4.  Numerical optimization of alignment reproducibility for customizable surgical guides.

Authors:  Thomas Kroes; Edward Valstar; Elmar Eisemann
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-11       Impact factor: 2.924

5.  3D-printed navigation template in proximal femoral osteotomy for older children with developmental dysplasia of the hip.

Authors:  Pengfei Zheng; Peng Xu; Qingqiang Yao; Kai Tang; Yue Lou
Journal:  Sci Rep       Date:  2017-03-21       Impact factor: 4.379

6.  The Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications.

Authors:  Jun-Dong Chang; In-Sung Kim; Atul M Bhardwaj; Ramachandra N Badami
Journal:  Hip Pelvis       Date:  2017-03-06

7.  Augmented Reality Based Navigation for Computer Assisted Hip Resurfacing: A Proof of Concept Study.

Authors:  He Liu; Edouard Auvinet; Joshua Giles; Ferdinando Rodriguez Y Baena
Journal:  Ann Biomed Eng       Date:  2018-05-23       Impact factor: 3.934

8.  Periacetabular osteotomy using three-dimensional cutting and reposition guides: a cadaveric study.

Authors:  Stephan H Wirth; Stefan Rahm; Atul F Kamath; Claudio Dora; Patrick O Zingg
Journal:  J Hip Preserv Surg       Date:  2019-10-24

Review 9.  Computer-assisted orthopaedic surgery and robotic surgery in total hip arthroplasty.

Authors:  Nobuhiko Sugano
Journal:  Clin Orthop Surg       Date:  2013-02-20
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.