OBJECTIVE: To evaluate the feasibility of using endovascular repair to treat penetrating arterial injuries with covered stents. Feasibility was examined according to the circumferential extent of the injury.Entities:
Mesh:
Year: 2011 PMID: 21915495 PMCID: PMC3161223 DOI: 10.1590/s1807-59322011000800020
Source DB: PubMed Journal: Clinics (Sao Paulo) ISSN: 1807-5932 Impact factor: 2.365
Figure 1Controlled section of the vessel wall in a lesion with a circumferential extent of 33%.
Figure 2Lesions confirmed by arteriograms in the four groups.
Figure 3Control arteriograms showing patency and blood flow in a successful case from each of the four groups.
Doppler ultrasonography parameters (means ± standard deviation) before the lesion was created and after the placement of the covered stent and control arteriography with a perforating lesion model.
| Doppler ultrasonography parameters | Before | After | Student's | Wilcoxon signed-rank test |
| Maximum arterial diameter | 0.50±0.04 | 0.45±0.07 | T = 15; | |
| Peak systolic velocity | 56.18±13.83 | 65.28±17.48 | T = 18; | |
| Peak diastolic velocity | 16.14±5.53 | 24.40±9.96 | T = 9; | |
| Resistance index | 0.73±0.08 | 0.67±0.11 | T = 24.5; |
Doppler ultrasonography parameters (means ± standard deviation) before the lesion was created and after the placement of the covered stent and control arteriography in control and experimental groups.
| Doppler ultra-sonography parameters | Group 1 | Group 2 | Group 3 | Kruskal-Wallis |
| Before | 0.50±0.03 | 0.52±0.07 | 0.47±0.04 | |
| After | 0.44±0.06 | 0.46±0.08 | 0.47±0.05 | |
| Mean difference | -0.06 | -0.06 | -0.01 | H = 1.75; |
| Before | 48.48±7.05 | 62.22±20.18 | 54.84±10.04 | |
| After | 61.64±15.00 | 71.18±21.35 | 62.47±18.05 | |
| Mean difference | 13.26 | 8.96 | 4.10 | H = 0.22; |
| Before | 16.36±3.28 | 16.24±7.48 | 15.75±6.59 | |
| After | 20.98±3.70 | 26.10±3.51 | 23.26±19.11 | |
| Mean difference | 4.62 | 6.66 | 10.8 | H = 0.61; |
| Before | 0.66±0.06 | 0.79±0.09 | 0.73±0.03 | |
| After | 0.70±0.07 | 0.62±0.08 | 0.69±0.17 | |
| Mean difference | 0.04 | -0.16 | -0.03 | H = 4.52; |
Table 3Arteriography findings before and after the endovascular procedure to place the covered stent in the left common carotid artery in control and experimental groups.