| Literature DB >> 21915479 |
Mário L R Monteiro1, Rodrigo B S Moritz, Hélio Angotti Neto, Joseph E Benabou.
Abstract
OBJECTIVE: To compare superior ophthalmic vein blood flow parameters measured with color Doppler imaging in patients with congestive Graves' orbitopathy before and after treatment and in normal controls.Entities:
Mesh:
Year: 2011 PMID: 21915479 PMCID: PMC3161207 DOI: 10.1590/s1807-59322011000800004
Source DB: PubMed Journal: Clinics (Sao Paulo) ISSN: 1807-5932 Impact factor: 2.365
Detection and direction of blood flow in the superior ophthalmic vein using color Doppler imaging in patients with Graves' orbitopathy and control subjects.
| Superior orbital vein blood flow | ||||
| Anteroposterior | Posteroanterior (reverse) | Not detected | Number of orbits | |
| 13 (59.1%) | 4 (18.2%) | 5 (22.7%) | 22 (100%) | |
| 21 (95.4%) | 0 (0.0%) | 1 (4.5%) | 22 (100%) | |
| 29 (90.6%) | 0 (0.0%) | 3 (9.4%) | 32 (100%) | |
| 63 (82.9%) | 4 (5.3%) | 9 (11.8%) | 76 (100%) | |
Fisher's exact test (p = 0.007, controls compared with orbitopathy before treatment).
Fisher's exact test (p = 0.638, controls compared with orbitopathy after treatment).
Comparison of blood flow parameters in the superior ophthalmic vein (SOV) in patients with Graves' orbitopathy and controls.
| Mean (range) velocity (cm/s) | |||
| SOV maximum velocity | SOV minimum velocity | Differential flow velocity | |
| 3.07 | 2.11 | 0.96 | |
| 7.80 | 5.31 | 2.48 | |
| 7.49 | 5.02 | 2.47 | |
p<0.05, paired t-test, comparing GO orbits before and after treatment.
p<0.05, unpaired t-test, active GO compared with controls.