Literature DB >> 21914684

Heart rate variability to assess ventilatory thresholds: reliable in cardiac disease?

L Mourot1, N Tordi, M Bouhaddi, D Teffaha, C Monpere, J Regnard.   

Abstract

BACKGROUND: The first (VT1) and second (VT2) ventilatory thresholds are landmarks to tailor exercise rehabilitation in coronary artery disease (CAD) or chronic heart failure (CHF). Methods allowing VT1 and VT2 determination based on heart rate variability (HRV) have been proposed but not yet evaluated in these patients.
DESIGN: To determine the heart rate (HR) associated with VT1 and VT2 by three methods of HRV analyses.
METHODS: Fourteen CHF and 24 CAD patients performed an exercise test on a cycle ergometer (10 -W every minute until exhaustion). VT1 and VT2 were determined with the 'respiratory equivalent' method. HR at VT1 was determined with the standard deviation (SD) of R⊟R intervals (VT(SD)) and of the instantaneous beat-to-beat variability of the Poincaré plot method (VT(Poincaré)). HR at VT1 and VT2 was determined through a time-varying HRV analysis method (VT(TV1) and VT(TV2), respectively).
RESULTS: HR at VT(SD) was significantly higher than HR at VT1. No significant differences were observed between HR at VT(Poincaré), VT(TV1), and at VT1, nor between HR at VT(TV2) and VT2. HR at VT(SD), VT(Poincaré), and VT1 were significantly correlated, but with a low r (2) value and a large mean HR difference. With the time-varying method, the mean HR difference was lower than 5% and the correlation coefficients were higher (especially for VT(TV2)).
CONCLUSIONS: SD and Poincaré plot methods lead to substantial inaccuracy in HR estimates. The time-varying HRV analysis led to strong correlation coefficients and low limits of agreement. Therefore, this method may be a promising, low-cost tool for non-invasive assessment of the ventilatory thresholds in cardiac disease.

Entities:  

Mesh:

Year:  2011        PMID: 21914684     DOI: 10.1177/1741826711423115

Source DB:  PubMed          Journal:  Eur J Prev Cardiol        ISSN: 2047-4873            Impact factor:   7.804


  3 in total

1.  Detection of structural changes in tachogram series for the diagnosis of atrial fibrillation events.

Authors:  Francesca Ieva; Anna Maria Paganoni; Paolo Zanini
Journal:  Comput Math Methods Med       Date:  2013-04-18       Impact factor: 2.238

2.  Influence of exercise modality on agreement between gas exchange and heart rate variability thresholds.

Authors:  F A Cunha; R A Montenegro; A W Midgley; F Vasconcellos; P P Soares; P Farinatti
Journal:  Braz J Med Biol Res       Date:  2014-07-08       Impact factor: 2.590

3.  Non-exhaustive double effort test is reliable and estimates the first ventilatory threshold intensity in running exercise.

Authors:  Lucas Dantas Maia Forte; Fúlvia Barros Manchado-Gobatto; Roberta Cunha Matheus Rodrigues; Maria Cecília Gallani; Claudio Alexandre Gobatto
Journal:  J Sport Health Sci       Date:  2017-02-16       Impact factor: 7.179

  3 in total