The effect of ceramic restoration shade and thickness on the polymerization of light- and dual-cure resin cements.

E Kilinc1, S A Antonson, P C Hardigan, A Kesercioglu.   

Abstract

OBJECTIVES: Inadequately polymerized resin cements may negatively affect the clinical performance of cemented all-ceramic restorations. The purpose of this in vitro study was to evaluate the effect of ceramic thickness and shade on the microhardness of various light-cured (LC) and dual-cured (DC) resin cements. The amount of light transmission through the restoration was also evaluated to correlate the results.
METHODS: Three different brands of resin cements (Appeal/Ivoclar; Calibra/Dentsply; Nexus 2/Kerr) were used in LC and DC forms to prepare disk-shaped samples (0.5-mm thickness × 5-mm diameter) (n=15). Study group samples were light-cured for 40 seconds (Flashlite 1401/Discus Dental) through four shades (ETC1, ETC2, ETC3, ETC4) and four thicknesses (1 mm, 2 mm, 3 mm, 4 mm) of all-ceramic ingot discs (IPS Empress Esthetic/Ivoclar). Control samples were directly cured without the presence of ceramic. The light transmission through various shades and thicknesses of ceramics was measured using a hand-held radiometer (Demetron, Kerr). Vickers microhardness measurements were performed (Micromet/Buehler) at 24 hours following dark storage in 37°C water. Correlation between ceramic shade, thickness, and light intensity readings (mW/cm2) with respect to microhardness was statistically evaluated using analysis of variance (p=0.05).
RESULTS: Ceramic thickness of 3 mm and/or above significantly decreased the microhardness values in all LC and DC groups (p<0.0001). Ceramic shade had a significant effect only on Calibra in both LC and DC groups (p<0.0001). Microhardness values of LC groups were significantly lower than DC groups (p<0.0001). Control groups had significantly higher hardness values in all cement groups (p<0.0001). There was a significant correlation between the amount of light transmitted and hardness (p=0.000).
CONCLUSION: The ceramic thickness has a more intense effect on polymerization compared to the ceramic shade. Overlying ceramic thickness of 3 mm and above was found to adversely affect the polymerization of LC and DC resin cements and therefore a 3-mm thickness was considered the critical threshold.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21913860     DOI: 10.2341/10-206-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  22 in total

1.  Effect of two lasers on the polymerization of composite resins: single vs combination.

Authors:  Jung-Hoon Ro; Sung-Ae Son; Jeong-kil Park; Gye-Rok Jeon; Ching-Chang Ko; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2015-04-17       Impact factor: 3.161

2.  Light curing through glass ceramics: effect of curing mode on micromechanical properties of dual-curing resin cements.

Authors:  Simon Flury; Adrian Lussi; Reinhard Hickel; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2013-08-09       Impact factor: 3.573

3.  Light curing through glass ceramics with a second- and a third-generation LED curing unit: effect of curing mode on the degree of conversion of dual-curing resin cements.

Authors:  Simon Flury; Adrian Lussi; Reinhard Hickel; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2013-02-08       Impact factor: 3.573

4.  Effect of Different Thicknesses of Pressable Ceramic Veneers on Polymerization of Light-cured and Dual-cured Resin Cements.

Authors:  Seok-Hwan Cho; Arnaldo Lopez; David W Berzins; Soni Prasad; Kwang Woo Ahn
Journal:  J Contemp Dent Pract       Date:  2015-05-01

5.  Influence of thickness and translucency of lithium disilicate ceramic on degree of conversion of resinous materials.

Authors:  Priscila-Christiane-Suzy Liporoni; Alcira-Cinthia-Rodríguez Ponce; Maiara-Rodrigues de Freitas; Rayssa-Ferreira Zanatta; Maria-Clara-Santos Pereira; Anderson Catelan
Journal:  J Clin Exp Dent       Date:  2020-08-01

6.  Degree of conversion and microhardness of resin cements photoactivated through glass ceramic.

Authors:  Carolina-Nemesio-de Barros Pereira; Cláudia-Silami Magalhães; Frederico-Santos Lages; Raquel-da Conceição Ferreira; Emerson-Hamilton da Silva; Rodrigo-Richard da Silveira; Elaine-Carballo-Siqueira Corrêa; Cristiano-Leite Fantini; Allyson-Nogueira Moreira
Journal:  J Clin Exp Dent       Date:  2021-11-01

7.  Minimum Radiant Exposure and Irradiance for Triggering Adequate Polymerization of a Photo-Polymerized Resin Cement.

Authors:  Qi Li; Hong-Lei Lin; Ming Zheng; Mutlu Ozcan; Hao Yu
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

8.  Light transmittance and surface roughness of a feldspathic ceramic CAD-CAM material as a function of different surface treatments.

Authors:  Çağrı Ural; İbrahim Duran; Betül Evmek; İdris Kavut; Seda Cengiz; Emir Yuzbasioglu
Journal:  BMC Oral Health       Date:  2016-07-15       Impact factor: 2.757

9.  Light transmittance of zirconia as a function of thickness and microhardness of resin cements under different thicknesses of zirconia.

Authors:  Isil Cekic-Nagas; Ferhan Egilmez; Gulfem Ergun; Bekir-Murat Kaya
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-03-01

10.  Light curing of dual cure resin cement.

Authors:  Hoon-Sang Chang
Journal:  Restor Dent Endod       Date:  2013-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.