Literature DB >> 21913268

Molecular dynamic-secondary ion mass spectrometry (D-SIMS) ionized by co-sputtering with C60+ and Ar+.

Yun-Wen You1, Hsun-Yun Chang, Wei-Chun Lin, Che-Hung Kuo, Szu-Hsian Lee, Wei-Lun Kao, Guo-Ji Yen, Chi-Jen Chang, Chi-Ping Liu, Chih-Chieh Huang, Hua-Yang Liao, Jing-Jong Shyue.   

Abstract

Dynamic secondary ion mass spectrometry (D-SIMS) analysis of poly(ethylene terephthalate) (PET) and poly(methyl methacrylate) (PMMA) was conducted using a quadrupole mass analyzer with various combinations of continuous C(60)(+) and Ar(+) ion sputtering. Individually, the Ar(+) beam failed to generate fragments above m/z 200, and the C(60)(+) beam generated molecular fragments of m/z ~1000. By combining the two beams, the auxiliary Ar(+) beam, which is proposed to suppress carbon deposition due to C(60)(+) bombardment and/or remove graphitized polymer, the sputtering range of the C(60)(+) beam is extended. Another advantage of this technique is that the high sputtering rate and associated high molecular ion intensity of the C(60)(+) beam generate adequate high-mass fragments that mask the damage from the Ar(+) beam. As a result, fragments at m/z ~900 can be clearly observed. As a depth-profiling tool, the single C(60)(+) beam cannot reach a steady state for either PET or PMMA at high ion fluence, and the intensity of the molecular fragments produced by the beam decreases with increasing C(60)(+) fluence. As a result, the single C(60)(+) beam is suitable for profiling surface layers with limited thickness. With C(60)(+)-Ar(+) co-sputtering, although the initial drop in intensity is more significant than with single C(60)(+) ionization because of the damage introduced by the auxiliary Ar(+), the intensity levels indicate that a more steady-state process can be achieved. In addition, the secondary ion intensity at high fluence is higher with co-sputtering. As a result, the sputtered depth is enhanced with co-sputtering and the technique is suitable for profiling thick layers. Furthermore, co-sputtering yields a smoother surface than single C(60)(+) sputtering.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Year:  2011        PMID: 21913268     DOI: 10.1002/rcm.5181

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  1 in total

1.  Gas-cluster ion sputtering: Effect on organic layer morphology.

Authors:  Christopher M Goodwin; Zachary E Voras; Thomas P Beebe
Journal:  J Vac Sci Technol A       Date:  2018-07-27       Impact factor: 2.427

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.