Literature DB >> 21913153

[The active middle ear implant for the rehabilitation of sensorineural, mixed and conductive hearing losses].

G M Sprinzl1, A Wolf-Magele, J Schnabl, V Koci.   

Abstract

Active middle ear implants, such as the Vibrant Soundbridge, are used as an important part in the rehabilitation of sensorineural, conductive hearing, or mixed hearing loss. The attachment of the Vibrant Soundbridge at the round window and the usage of the Vibroplasty couplers strongly expanded the application of the Vibrant Soundbridge.The Vibrant Soundbridge is developed for patients who have an intolerance to hearing aids and a moderate to profound sensorineural hearing loss. The VSB also provides an optimal solution for patients with failed middle ear reconstructions or patients with atresia. To capture the improvement with the VSB Implant with different hearing losses a literature analysis was conducted. The functional gain was analyzed for 107 patients with conductive hearing loss and for 214 patients with sensorineural hearing loss out of 14 studies.Patients with conductive and mixed hearing loss resulted in a functional gain from 30 to 58 dB with the VSB. Patients with a pure sensorineural hearing loss showed a functional gain of 23-30 dB. The VSB bone conduction threshold shift was analyzed for all studies conducted in the years between 2000 and 2009. In 11 of the 16 studies there was no significant (p=0.05) change found. In 5 studies, the pre- to post-surgical bone conduction threshold shift was less than 10 dB. None of these studies measured a threshold shift of more than 10 dB.The flexible attachment at either the long process of the incus with sensorineural hearing loss, with an conductive hearing loss at the round window or the use of Vibroplasty couplers at the oval window, head of the stapes or round window makes the VSB an extremely versatile instrument. If patients can't wear conventional hearing aids, had failed middle ear reconstructions or atresia the VSB presents, due to the significant hearing improvement in any type of hearing loss, an ideal solution. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2011        PMID: 21913153     DOI: 10.1055/s-0031-1286321

Source DB:  PubMed          Journal:  Laryngorhinootologie        ISSN: 0935-8943            Impact factor:   1.057


  6 in total

1.  Vibrant Soundbridge middle ear implantations: experience at National University Hospital Singapore.

Authors:  Lynne Hsueh Yee Lim; Jocelynne Del Prado; Ling Xiang; Abdul Rahman Bin Yusof; Jenny Hooi Yin Loo
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-03-28       Impact factor: 2.503

2.  The Hannover Coupler V2: Audiological outcomes of a round window coupler for the Vibrant Soundbridge.

Authors:  Nicole Knölke; Dawid Murawski; Nina Wardenga; Susan Busch; Hannes Maier; Thomas Lenarz
Journal:  Laryngoscope Investig Otolaryngol       Date:  2022-05-28

Review 3.  Diseases of the middle ear in childhood.

Authors:  Amir Minovi; Stefan Dazert
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2014-12-01

4.  The Influence of Piezoelectric Transducer Stimulating Sites on the Performance of Implantable Middle Ear Hearing Devices: A Numerical Analysis.

Authors:  Houguang Liu; Yu Zhao; Jianhua Yang; Zhushi Rao
Journal:  Micromachines (Basel)       Date:  2019-11-14       Impact factor: 2.891

5.  Evaluation of Round Window Stimulation Performance in Otosclerosis Using Finite Element Modeling.

Authors:  Shanguo Yang; Dan Xu; Xiaole Liu
Journal:  Comput Math Methods Med       Date:  2016-02-29       Impact factor: 2.238

6.  Redesign of the Hannover Coupler: Optimized Vibration Transfer from Floating Mass Transducer to Round Window.

Authors:  Mathias Müller; Rolf Salcher; Nils Prenzler; Thomas Lenarz; Hannes Maier
Journal:  Biomed Res Int       Date:  2018-05-14       Impact factor: 3.411

  6 in total