Literature DB >> 21911194

Prospective randomized comparison of the EasyTube and the esophageal-tracheal Combitube airway devices during general anesthesia with mechanical ventilation.

Luis A Gaitini1, Boris Yanovsky, Mostafa Somri, Riad Tome, Pedro Charco Mora, Michael Frass, Allan P Reed, Sonia Vaida.   

Abstract

STUDY
OBJECTIVE: To evaluate the ease of use of two airway devices, the EasyTube (EzT) versus the esophageal-tracheal Combitube (ETC).
DESIGN: Prospective, randomized controlled trial.
SETTING: University hospital.
SUBJECTS: 80 adult, ASA physical status 1 and 2 patients scheduled for elective surgery.
INTERVENTIONS: Patients' tracheas were intubated with the EzT or the ETC in randomized fashion. MEASUREMENTS: Difficulty of insertion, time to achieve an effective airway, insertion success rate, maneuvers to achieve an effective airway, oropharyngeal leak pressure, intracuff pressure, ventilatory parameters, success rate of gastric tube insertion, and frequency of adverse effects were compared. MAIN
RESULTS: Insertion was easier in the EzT than in ETC; insertion of the EzT was rated easy in 36 7 cases and moderately difficult in 4 cases versus 26 and 14 cases, respectively, for the ETC (P = 0.014). Less time was required to achieve an effective airway with the EzT than the ETC: 19.4 ± 5.3 sec versus 30.6 ± 4.1 seconds, respectively (P < 0.001). Oropharyngeal leak pressure was higher with the EzT than the ETC (34.3 ± 5.95 vs 31.6 ± 2.42 cm H(2)O; P = 0.011). Peak airway pressures for the EZT and the ETC were 22.2 ± 0.99 cm H(2)0 and 33.7 ± 1.82 cm H(2)O, respectively (P < 0.001). Gastric tube insertion was successful with both devices; however, the EzT allowed insertion of gastric tubes of wider diameter. No severe perioperative adverse events were recorded for either device.
CONCLUSION: The EzT has distinct advantages over the ETC in airway management, including shorter time to achieve an effective airway and easier insertion.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21911194     DOI: 10.1016/j.jclinane.2011.01.007

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  6 in total

Review 1.  [Supraglottic airway devices].

Authors:  K Schwarzkopf
Journal:  Med Klin Intensivmed Notfmed       Date:  2012-09-26       Impact factor: 0.840

Review 2.  Current status of the EasyTube: a review of the literature.

Authors:  Sonia J Vaida; Luis A Gaitini; Michael Frass; Jansie Prozesky
Journal:  Rom J Anaesth Intensive Care       Date:  2015-04

3.  Comparison of combitube, easy tube and tracheal tube for general anesthesia.

Authors:  Ashok Kumar Sethi; Manisha Desai; Asha Tyagi; Surendra Kumar
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2014-10

4.  The EasyTube during general anesthesia for minor surgery: A randomized, controlled trial.

Authors:  Oliver Robak; Sonia Vaida; Luis Gaitini; Andreas Thierbach; Ricardo Urtubia; Peter Krafft; Michael Frass
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.889

5.  The Development and Application of Airway Devices in China.

Authors:  Xiangdong Chen; Wuhua Ma; Renyu Liu; Shanglong Yao
Journal:  Transl Perioper Pain Med       Date:  2016-10-01

6.  Inter-center comparison of EasyTube and endotracheal tube during general anesthesia in minor elective surgery.

Authors:  Oliver Robak; Sonia Vaida; Mostafa Somri; Luis Gaitini; Lisa Füreder; Michael Frass; Lukasz Szarpak
Journal:  PLoS One       Date:  2017-06-02       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.