Literature DB >> 21910014

Liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source for elemental mass spectrometry: preliminary parametric evaluation and figures of merit.

C Derrick Quarles1, Anthony J Carado, Charles J Barinaga, David W Koppenaal, R Kenneth Marcus.   

Abstract

A new, low-power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (<20 mA) and solution flow rates (<50 μL min(-1)), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications, other than removing the electrospray ionization source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary and a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra, including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements indicate that sodium concentrations of up to 50 μg mL(-1) generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. While solution-based concentration LOD levels of 0.02-2 μg mL(-1) are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to single-nanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of <50 μL min(-1), and gas flow rates <10 mL min(-1)) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively coupled plasma sources typically employed in elemental mass spectrometry.

Entities:  

Year:  2011        PMID: 21910014     DOI: 10.1007/s00216-011-5359-7

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Preliminary Figures of Merit for Isotope Ratio Measurements: The Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Ionization Source Coupled to an Orbitrap Mass Analyzer.

Authors:  Edward D Hoegg; Charles J Barinaga; George J Hager; Garret L Hart; David W Koppenaal; R Kenneth Marcus
Journal:  J Am Soc Mass Spectrom       Date:  2016-04-14       Impact factor: 3.109

2.  Fabrication and Characterizations of Axial View Liquid Electrode Plasma Atomic Emission Spectrometry for the Sensitive Determination of Trace Zinc, Cadmium, and Lead.

Authors:  Yueh-Han Huang; Daisuke Hirose; Jun Minami; Meng-Jiy Wang; Yuzuru Takamura
Journal:  Anal Chem       Date:  2022-06-02       Impact factor: 8.008

3.  Matrix-Assisted Plasma Atomization Emission Spectrometry for Surface Sampling Elemental Analysis.

Authors:  Xin Yuan; Xuefang Zhan; Xuemei Li; Zhongjun Zhao; Yixiang Duan
Journal:  Sci Rep       Date:  2016-01-14       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.