Literature DB >> 21909036

Instrumented spondylodesis in degenerative spondylolisthesis with bioactive glass and autologous bone: a prospective 11-year follow-up.

Janek Frantzén1, Juho Rantakokko, Hannu T Aro, Jyrki Heinänen, Sami Kajander, Eero Gullichsen, Esa Kotilainen, Nina C Lindfors.   

Abstract

A prospective long-term follow-up study of bioactive glass (BAG)-S53P4 and autogenous bone (AB) used as bone graft substitutes for posterolateral spondylodesis in treatment of degenerative spondylolisthesis during 1996 to 1998 was conducted. The surgical procedure was a standardized instrumented posterolateral fusion that used USS/VAS. BAG was implanted on the left side of the fusion bed and AB on the right side. The operative outcome was evaluated on x-rays and computed tomography scans, and a clinical examination was also performed. Seventeen patients (12 women, 5 men) participated in the 11-year follow-up. The mean Oswestry Disability Index score at the follow-up was 21 (range 0 to 52), compared with 49 (range 32 to 64) at the preoperative time. A solid bony fusion was seen on computed tomography scans on the AB side in all patients and on the BAG side in 12 patients. The fusion rate of all fusion sites (n=41) for BAG as a bone substitute was 88% at the L4/5 level and 88% at the L5/S1 level. The use of BAG as a bone graft extender can be considered as a good alternative in spinal surgery in the future.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21909036     DOI: 10.1097/BSD.0b013e31822a20c6

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  9 in total

1.  Clinical and radiographic evaluation of bioactive glass in posterior cervical and lumbar spinal fusion.

Authors:  Cédric Barrey; Théo Broussolle
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-06-24

2.  Bone graft materials for posterolateral fusion made simple: a systematic review.

Authors:  Matthew T Morris; Sandip P Tarpada; Woojin Cho
Journal:  Eur Spine J       Date:  2018-02-14       Impact factor: 3.134

3.  Clinical experience with the use of a spherical bioactive glass putty for cervical and lumbar interbody fusion.

Authors:  L Erik Westerlund; Mark Borden
Journal:  J Spine Surg       Date:  2020-03

Review 4.  [Application and research status of bioactive glass in bone repair].

Authors:  Yonghua Huang; Li Li; Zhanying Shi; Xu Cui; Haobo Pan; Bing Li
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-05-15

5.  Bioactive glass in cavitary bone defects: a comparative experimental study in rabbits.

Authors:  André Ferrari de França Camargo; André Mathias Baptista; Renato Natalino; Olavo Pires de Camargo
Journal:  Acta Ortop Bras       Date:  2015 Jul-Aug       Impact factor: 0.513

6.  Bioactive glass BAG-S53P4 for the adjunctive treatment of chronic osteomyelitis of the long bones: an in vitro and prospective clinical study.

Authors:  Lorenzo Drago; Delia Romanò; Elena De Vecchi; Christian Vassena; Nicola Logoluso; Roberto Mattina; Carlo Luca Romanò
Journal:  BMC Infect Dis       Date:  2013-12-10       Impact factor: 3.090

Review 7.  Clinical Applications of S53P4 Bioactive Glass in Bone Healing and Osteomyelitic Treatment: A Literature Review.

Authors:  N A P van Gestel; J Geurts; D J W Hulsen; B van Rietbergen; S Hofmann; J J Arts
Journal:  Biomed Res Int       Date:  2015-10-04       Impact factor: 3.411

Review 8.  Bioactive Glasses: Frontiers and Challenges.

Authors:  Larry L Hench; Julian R Jones
Journal:  Front Bioeng Biotechnol       Date:  2015-11-30

Review 9.  Bone grafts and biomaterials substitutes for bone defect repair: A review.

Authors:  Wenhao Wang; Kelvin W K Yeung
Journal:  Bioact Mater       Date:  2017-06-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.