Literature DB >> 21908145

Flow-mediated vasodilation is augmented in a corkscrew collateral artery compared with that in a native artery in patients with thromboangiitis obliterans (Buerger disease).

Yuichi Fujii1, Noritaka Fujimura, Shinsuke Mikami, Tatsuya Maruhashi, Yasuki Kihara, Kazuaki Chayama, Kensuke Noma, Yukihito Higashi.   

Abstract

BACKGROUND: A healthy endothelium maintains vascular tone and structure. The purpose of this study was to evaluate endothelial function in corkscrew collateral arteries in Buerger disease.
METHODS: We measured flow-mediated vasodilation (FMD) in corkscrew arteries in 26 patients with Buerger disease, in control arteries in 26 healthy subjects, and in native arteries in 16 patients with Buerger disease.
RESULTS: Hyperemic flow was lower in corkscrew arteries than in native arteries in patients with Buerger disease and in control arteries in healthy subjects. There was no significant difference between hyperemic flow in patients with Buerger disease in whom measurements were performed in native arteries and that in healthy subjects. FMD was lower in corkscrew arteries and native arteries in patients with Buerger disease than in control arteries in healthy subjects. There was no significant difference between FMD in corkscrew arteries in patients with Buerger disease and in that in native arteries. The ratio of FMD to hyperemic flow was significantly smaller in native arteries in patients with Buerger disease than in corkscrew arteries and in control arteries in healthy subjects (5.5 ± 6.2 vs 8.8 ± 8.9 and 9.6 ± 7.6 mL/min, P < .001, respectively). There was no significant difference in the ratio of FMD to hyperemic flow between corkscrew arteries in Buerger disease and control arteries in healthy subjects. Nitroglycerin-induced vasodilation was similar in all leg arteries.
CONCLUSIONS: Endothelial function of a corkscrew collateral artery in patients with Buerger disease is maintained, while endothelial function is impaired in a native artery in Buerger disease.
Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21908145     DOI: 10.1016/j.jvs.2011.05.095

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  2 in total

1.  CFD simulation of blood flow inside the corkscrew collaterals of the Buerger's disease.

Authors:  Alireza Sharifi; Mohammad Charjouei Moghadam
Journal:  Bioimpacts       Date:  2016-03-28

2.  Endothelial dysfunction in patients with Buerger disease.

Authors:  Kimihiro Igari; Toshifumi Kudo; Takahiro Toyofuku; Yoshinori Inoue
Journal:  Vasc Health Risk Manag       Date:  2017-08-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.