Literature DB >> 21908124

Pancreaticobiliary duct changes of periampullary carcinomas: quantitative analysis at MR imaging.

Dong Sheng Wu1, Wei Xia Chen, Xiao Dong Wang, Riwaz Acharya, Xing Hua Jiang.   

Abstract

PURPOSE: To quantitatively analyse the pancreaticobiliary duct changes of periampullary carcinomas with volumetric interpolated breath-hold examination (VIBE) and true fast imaging with steady-state precession (true FISP) sequence, and investigate the value of these findings in differentiation and preoperative evaluation.
MATERIALS AND METHODS: Magnetic resonance (MR) images of 71 cases of periampullary carcinomas (34 cases of pancreatic head carcinoma, 16 cases of intrapancreatic bile duct carcinoma and 21 cases of ampullary carcinoma) confirmed histopathologically were analysed. The maximum diameter of the common bile duct (CBD) and main pancreatic duct (MPD), dilated pancreaticobiliary duct angle and the distance from the end of the proximal dilated pancreaticobiliary duct to the major papilla were measured. Analysis of variance and the Chi-squared test were performed.
RESULTS: These findings showed significant differences among the three subtypes: the distance from the end of proximal dilated pancreaticobiliary duct to the major papilla and pancreaticobiliary duct angle. The distance and the pancreaticobiliary duct angle were least for ampullary carcinoma among the three subtypes. The percentage of dilated CBD was 94.1%, 93.8%, and 100% for pancreatic head carcinoma, intrapancreatic bile duct carcinoma and ampullary carcinoma, respectively. And that for the dilated MPD was 58.8%, 43.8%, and 42.9%, respectively.
CONCLUSION: Quantitative analysis of the pancreaticobiliary ductal system can provide accurate and objective assessment of the pancreaticobiliary duct changes. Although benefit in differential diagnosis is limited, these findings are valuable in preoperative evaluation for both radical resection and palliative surgery.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21908124     DOI: 10.1016/j.ejrad.2011.08.009

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  2 in total

1.  Differentiation of benign and malignant ampullary obstruction by multi-row detector CT.

Authors:  Wirana Angthong; Kran Jiarakoop; Kaan Tangtiang
Journal:  Jpn J Radiol       Date:  2018-05-21       Impact factor: 2.374

Review 2.  Magnetic resonance evaluations of biliary malignancy and condition at high-risk for biliary malignancy: Current status.

Authors:  Reiji Sugita
Journal:  World J Hepatol       Date:  2013-12-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.