Literature DB >> 21905898

A technique for removal of a fractured implant abutment screw.

Murat Kurt1, Ahmet Umut Güler, İbrahim Duran.   

Abstract

The aim of this technique report was to present a procedure for removal of a fractured implant abutment screw. Whatever the cause, when an abutment fracture has occurred, the fractured screw segment inside the implant must be removed. The methods used by the clinicians may include the use of an endo-explorer self-made screwdriver and the use of implant repair kit available for some implant systems. The advantage of the presented method is that it may be extended to other implant systems that do not have a special repair kit and also that the technique is simple and does not require special equipment.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21905898     DOI: 10.1563/AAID-JOI-D-11-00017

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  2 in total

Review 1.  Management of perishing implants with abutment screw fracture - A systematic review.

Authors:  Soja Raju; Vivek V Nair; Harsha Kumar Karunakaran; Noxy George Manjuran
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

2.  A novel technique to retrieve cold-welded implant abutment: A case series.

Authors:  Mahnaz Arshad; Hossein Ali Mahgoli; Kamran Rasouli; Sina Refoua
Journal:  Clin Case Rep       Date:  2019-08-16
  2 in total