Literature DB >> 21904229

Superior versus anteroinferior plating of the clavicle: a finite element study.

Philippe Favre1, Peter Kloen, David L Helfet, Clément M L Werner.   

Abstract

OBJECTIVES: Fixation plate positioning remains controversial in clavicle fracture reconstruction. Biomechanical studies favor a superior plate placement and clinical series report very low mechanical complications for anteroinferior plate placement. To clarify this apparent discrepancy, a biomechanical finite element analysis of the deformation mode, stress patterns, and peak stresses involved with superior and anteroinferior clavicle plate fixation was performed.
METHODS: Finite element models of the superior and anteroinferior reconstructions were built and the results were compared with those of the intact clavicle when loaded in axial compression and cantilever bending.
RESULTS: Superior plate placement was less likely to fail in axial compression but the anteroinferior plate placement was less likely to fail in cantilever bending. For all placements and loading modes, the region near the fracture gap experienced the highest stresses and was consequently critical for the behavior of the whole construct. The anteroinferior placement led to a deformation mode similar to the intact clavicle in both loading configurations, whereas the deformation mode with the superior placement was non-physiological.
CONCLUSIONS: Anterorinferior plating is generally preferable, because it induces deformation modes similar to the intact clavicle and is less likely to fail during normal physiological loading (cantilever bending). Superior placement of the reconstruction plate may be recommended for a patient with a high risk of shoulder impacts (axial compression). Design improvements in the bridging area of the plate and special attention to obtain a good fixation around the fracture could reduce plate failures and provide a stiffer construct.

Entities:  

Mesh:

Year:  2011        PMID: 21904229     DOI: 10.1097/BOT.0b013e3182143e06

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  11 in total

1.  Strength analysis of clavicle fracture fixation devices and fixation techniques using finite element analysis with musculoskeletal force input.

Authors:  Cronskär Marie
Journal:  Med Biol Eng Comput       Date:  2015-04-08       Impact factor: 2.602

2.  A Validated Open-Source Shoulder Finite Element Model and Investigation of the Effect of Analysis Precision.

Authors:  Sara Sadeqi; Andrew P Baumann; Vijay K Goel; Victoria Lilling; Stacey J L Sullivan
Journal:  Ann Biomed Eng       Date:  2022-07-26       Impact factor: 4.219

3.  Risk of fracture of the acromion depends on size and orientation of acromial bone tunnels when performing acromioclavicular reconstruction.

Authors:  Felix Dyrna; Celso Cruz Timm de Oliveira; Michael Nowak; Andreas Voss; Elifho Obopilwe; Sepp Braun; Leo Pauzenberger; Andreas B Imhoff; Augustus D Mazzocca; Knut Beitzel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-10-06       Impact factor: 4.342

4.  A single centre experience of pre-contoured clavicle plates by an anterior approach.

Authors:  Eoin J Fahey; John G Galbraith; Ken Kaar
Journal:  J Orthop       Date:  2019-02-27

5.  Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study.

Authors:  Langqing Zeng; Haifeng Wei; Yanjie Liu; Wen Zhang; Yao Pan; Wei Zhang; Changqing Zhang; Bingfang Zeng; Yunfeng Chen
Journal:  PLoS One       Date:  2015-05-12       Impact factor: 3.240

6.  Superior versus anteroinferior plating of displaced midshaft clavicular fracture in patients older than 60 years.

Authors:  Minpeng Lu; Hao Qiu; Xin Zhou; Cody S Lee; Dianming Jiang; Jing Dong; Zhengxue Quan
Journal:  J Int Med Res       Date:  2017-03-21       Impact factor: 1.671

7.  TREATMENT OF MIDSHAFT CLAVICLE FRACTURE WITH SUPERIOR PLATE PLACEMENT.

Authors:  Bekir Eray Kilinc; Yunus Oc; Ramazan Erden Erturer
Journal:  Acta Ortop Bras       Date:  2020 Mar-Apr       Impact factor: 0.513

8.  Finite element analysis of spiral plate and Herbert screw fixation for treatment of midshaft clavicle fractures.

Authors:  Xiaojuan Zhang; Xiaodong Cheng; Bing Yin; Jianzhao Wang; Sheng Li; Guobin Liu; Zusheng Hu; Weiwei Wu; Yingze Zhang
Journal:  Medicine (Baltimore)       Date:  2019-08       Impact factor: 1.817

Review 9.  Operative versus nonoperative treatment for displaced midshaft clavicle fractures: a meta-analysis based on current evidence.

Authors:  Xin-Hua Wang; Wei-Jun Guo; A-Bing Li; Guang-Jun Cheng; Tao Lei; You-Ming Zhao
Journal:  Clinics (Sao Paulo)       Date:  2015-08       Impact factor: 2.365

10.  Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study.

Authors:  Alex K Gilde; Clifford B Jones; Debra L Sietsema; Martin F Hoffmann
Journal:  J Orthop Surg Res       Date:  2014-07-04       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.