Literature DB >> 21904227

Femoral neck shortening and varus collapse after navigated fixation of intracapsular femoral neck fractures.

Yoram A Weil1, Amal Khoury, Imad Zuaiter, Ori Safran, Meir Liebergall, Rami Mosheiff.   

Abstract

OBJECTIVE: Assessing femoral neck shortening (FNS) and varus collapse after internal fixation of femoral neck fractures using computerized navigation (CN).
DESIGN: Retrospective cohort study. SETTINGS: Academic Level I trauma center. PATIENTS AND METHODS: Forty-one patients who had healed femoral neck fractures treated with CN between the years 2003 and 2008. Average age was 65 years (range, 14-91 years). Thirty-six patients had nondisplaced fractures and five had displaced fractures. INTERVENTION: Screws were placed using CN in an inverted triangle formation Follow-up films were digitized into a PACS system, calibrated, and analyzed using CAD software. OUTCOME MEASURES: The following parameters were recorded: abductor lever arm shortening (termed x), corresponding vertical femur shortening (termed y), and the resultant femoral neck shortening vector (z). Fifteen patients were available for clinical outcome measures by the means of SF-12 survey
RESULTS: Significant FNS of the x component (greater than 5 mm) occurred in 30 of 42 (71%) patients with severe shortening (greater than 10 mm) in 25% of the patients. Significant y shortening occurred in 43% of the patients and severe shortening in 17%. Overall (z) femoral neck shortening occurred in 56% of the patients with severe shortening in 22% of patients. Varus collapse (greater than 5°) did not occur in any patient. Screw pullout (greater than 5 mm) occurred in 17 (41%) patients. Seven patients required late (greater than 6 months) arthroplasty postoperatively. FNS did not significantly correlate with fracture type, quality of reduction, age, or neck shaft angle. SF-12 results were negatively correlated with overall FNS.
CONCLUSIONS: Our results show a high degree of FNS associated with the use of CN for fixation of femoral neck fractures, similar to recently published series using nonnavigated implants. However, no varus collapse occurred in our series. Our preliminary clinical data show a trend toward an adverse effect of FNS on quality-of-life measures.

Entities:  

Mesh:

Year:  2012        PMID: 21904227     DOI: 10.1097/BOT.0b013e318214f321

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  16 in total

1.  Non-parallel screw fixation for femoral neck fractures in young adults.

Authors:  Sherif Galal; Mohamed Nagy
Journal:  J Clin Orthop Trauma       Date:  2017-07-15

Review 2.  [Femoral neck fractures in young patients].

Authors:  S Fitschen-Oestern; S Lippross; T Klüter; P Behrend; M Weuster; A Seekamp
Journal:  Unfallchirurg       Date:  2016-09       Impact factor: 1.000

3.  Association of the lateral wall integrity with clinical outcomes in older patients with intertrochanteric hip fractures treated with the proximal femoral nail anti-rotation-Asia.

Authors:  Zhaoman Shi; Minfei Qiang; Xiaoyang Jia; Kun Zhang; Yanxi Chen
Journal:  Int Orthop       Date:  2021-09-21       Impact factor: 3.075

4.  Comparison Between Femoral Neck Systems and Cannulated Cancellous Screws in Treating Femoral Neck Fractures: A Meta-Analysis.

Authors:  Peng Tian; Lan Kuang; Zhi-Jun Li; Gui-Jun Xu; Xin Fu
Journal:  Geriatr Orthop Surg Rehabil       Date:  2022-07-06

5.  Effect of Fracture Reduction with Different Medial Cortical Support on Stability After Cephalomedullary Nail Fixation of Unstable Pertrochanteric Fractures: A Biomechanical Analysis.

Authors:  Ling Ling; Zhongyong Qu; Kaihua Zhou
Journal:  Indian J Orthop       Date:  2021-06-30       Impact factor: 1.033

6.  Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients.

Authors:  Jingbo Cheng; Mingli Feng; Huaijian Hu; Zhihua Gao; Jingwei Wu; Shibao Lu
Journal:  J Orthop Surg Res       Date:  2021-06-09       Impact factor: 2.359

7.  Femoral neck system versus inverted cannulated cancellous screw for the treatment of femoral neck fractures in adults: a preliminary comparative study.

Authors:  Yunfeng Tang; Zhen Zhang; Limin Wang; Wei Xiong; Qian Fang; Guanglin Wang
Journal:  J Orthop Surg Res       Date:  2021-08-16       Impact factor: 2.359

8.  Addressing posterior tilt displacement during surgery to lower failure risk of sub-capital Garden types 1 and 2 femoral fractures.

Authors:  Ely L Steinberg; Assaf Albagli; Nimrod Snir; Moshe Salai; Amal Khoury; Tomer Ben-Tov; Shai Factor
Journal:  Arch Orthop Trauma Surg       Date:  2021-05-06       Impact factor: 2.928

9.  Presence of a nail in the medullary canal; is it enough to prevent femoral neck shortening in trochanteric fracture?

Authors:  Hyung Keun Song; Han Kuk Yoon; Kyu Hyun Yang
Journal:  Yonsei Med J       Date:  2014-09       Impact factor: 2.759

10.  Analysis on risk factors for neck shortening after internal fixation for Pauwels II femoral neck fracture in young patients.

Authors:  Fulong Zhao; Lijuan Guo; Xuefei Wang; Yakui Zhang
Journal:  Eur J Med Res       Date:  2021-06-24       Impact factor: 2.175

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.