BACKGROUND AND PURPOSE: DWI by using higher b-values provides tissue diffusivity with less T2 shinethrough effect. VCD in the abscess cavity correlates with ADC values. The purpose of this study was to investigate which b-value-derived ADC correlates better with VCD. MATERIALS AND METHODS: Thirty patients with brain abscess underwent conventional MR imaging and DWI with b = 1000, 2000, and 3000 s/mm(2) on a 3T MR imaging scanner. ADC values were quantified by placing regions of interest inside the abscess cavity in all sections where the lesion was apparent on coregistered ADC maps derived from different b-values. VCD was measured on pus aspirated. RESULTS: An increase in b-value was associated with a decrease in ADC values in normal parenchyma as well as in the abscess cavity. The most significant negative correlation of VCD was observed with b = 3000 s/mm(2) (r = -0.98, P = .01). CONCLUSIONS: VCD in the abscess cavity can be best assessed at b = 3000 s/mm(2) secondary to the reduction in the T2 shinethrough effect. DWI with b = 3000 s/mm(2) is of promising value in the assessment of the therapeutic response of brain abscess.
BACKGROUND AND PURPOSE: DWI by using higher b-values provides tissue diffusivity with less T2 shinethrough effect. VCD in the abscess cavity correlates with ADC values. The purpose of this study was to investigate which b-value-derived ADC correlates better with VCD. MATERIALS AND METHODS: Thirty patients with brain abscess underwent conventional MR imaging and DWI with b = 1000, 2000, and 3000 s/mm(2) on a 3T MR imaging scanner. ADC values were quantified by placing regions of interest inside the abscess cavity in all sections where the lesion was apparent on coregistered ADC maps derived from different b-values. VCD was measured on pus aspirated. RESULTS: An increase in b-value was associated with a decrease in ADC values in normal parenchyma as well as in the abscess cavity. The most significant negative correlation of VCD was observed with b = 3000 s/mm(2) (r = -0.98, P = .01). CONCLUSIONS: VCD in the abscess cavity can be best assessed at b = 3000 s/mm(2) secondary to the reduction in the T2 shinethrough effect. DWI with b = 3000 s/mm(2) is of promising value in the assessment of the therapeutic response of brain abscess.
Authors: Brian J Archer; Till Uberruck; Julia J Mack; Khalid Youssef; Nanette N Jarenwattananon; Deniz Rall; Denis Wypysek; Martin Wiese; Bernhard Blumich; Matthias Wessling; M Luisa Iruela-Arispe; Louis-S Bouchard Journal: IEEE Trans Biomed Eng Date: 2018-07-18 Impact factor: 4.538
Authors: Rasheed Zakaria; Kumar Das; Maneesh Bhojak; Mark Radon; Carol Walker; Michael D Jenkinson Journal: Cancer Imaging Date: 2014-04-22 Impact factor: 3.909