D W Bradley, H A Fields, K A McCaustland, J E Maynard, R H Decker, R Whittington, L R Overby.
Abstract
A competitive binding radioimmunoassay (CBA) for antibody to hepatitis A virus (HAV) was evaluated and compared with a standard solid-phase radioimmunoassay for anti-HAV, CBA was found to be sensitive and specific for the detection of anti-HAV, as demonstrated by the 98% concordance of CBA and solid-phase radioimmunoassay test results. The standard CBA test was modified for the differential detection of acute (immunoglobulin M) and convalescent (immunoglobulin G) anti-HAV by incorporation of a step in which immunoglobulin G anti-HAV was preferentially absorbed with S. aureus cells (protein A). The modified CBA test was shown to be capable of differentiating between acute- and convalescent-phase sera. The modified CBAM test was able to detect immunoglobulin M anti-HAV up to approximately 4 weeks after the onset of illness.Entities:
Mesh:
Substances:
Year: 1979 PMID: 219016 PMCID: PMC272968 DOI: 10.1128/jcm.9.1.120-127.1979
Source DB: PubMed Journal: J Clin Microbiol ISSN: 0095-1137 Impact factor: 5.948