Literature DB >> 21899494

To mix or not to mix venous blood samples collected in vacuum tubes?

Anna Parenmark1, Eva Landberg.   

Abstract

BACKGROUND: There are recommendations to mix venous blood samples by inverting the tubes immediately after venipuncture. Though mixing allows efficient anticoagulation in plasma tubes and fast initiation of coagulation in serum tubes, the effect on laboratory analyses and risk of haemolysis has not been thoroughly evaluated.
METHODS: Venous blood samples were collected by venipuncture in vacuum tubes from 50 patients (10 or 20 patients in each group). Four types of tubes and 18 parameters used in routine clinical chemistry were evaluated. For each patient and tube, three types of mixing strategies were used: instant mixing, no mixing and 5 min of rest followed by mixing.
RESULTS: Most analyses did not differ significantly in samples admitted to different mixing strategies. Plasma lactate dehydrogenase and haemolysis index showed a small but significant increase in samples omitted to instant mixing compared to samples without mixing. However, in one out of twenty non-mixed samples, activated partial thromboplastin time was seriously affected.
CONCLUSIONS: These results indicate that mixing blood samples after venipuncture is not mandatory for all types of tubes. Instant mixing may introduce interference for those analyses susceptible to haemolysis. However, tubes with liquid-based citrate buffer for coagulation testing should be mixed to avoid clotting.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21899494     DOI: 10.1515/CCLM.2011.705

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  10 in total

1.  Pre-analytical Errors in Glucose Estimation Results in Query on Diabetic Management.

Authors:  Preethi Loganathan; Sampath Kumar Gasper; Fathima Kader Afel; Selvakumar Kandaswamy
Journal:  Indian J Clin Biochem       Date:  2018-07-21

2.  Quality impact on diagnostic blood specimen collection using a new device to relieve venipuncture pain.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Indian J Clin Biochem       Date:  2013-04-03

3.  Targeting Rejection: Analysis of Specimen Acceptability and Rejection, and Framework for Identifying Interventions in a Single Tertiary Healthcare Facility.

Authors:  Lisa Rooper; Jamal Carter; John Hargrove; Sheri Hoffmann; Stefan Riedel
Journal:  J Clin Lab Anal       Date:  2016-09-15       Impact factor: 2.352

4.  Could light meal jeopardize laboratory coagulation tests?

Authors:  Gabriel Lima-Oliveira; Gian Luca Salvagno; Giuseppe Lippi; Elisa Danese; Matteo Gelati; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2014-10-15       Impact factor: 2.313

5.  Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study.

Authors:  Marija Kocijancic; Jelena Cargonja; Alma Delic-Knezevic
Journal:  Biochem Med (Zagreb)       Date:  2014-10-15       Impact factor: 2.313

Review 6.  Laboratory Diagnostics and Quality of Blood Collection.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Geraldo Picheth; Gian Cesare Guidi
Journal:  J Med Biochem       Date:  2015-07-14       Impact factor: 3.402

7.  Preanalytical Nonconformity Management Regarding Primary Tube Mixing in Brazil.

Authors:  Gabriel Lima-Oliveira; Gian Cesare Guidi; Andre Valpassos Pacifici Guimaraes; Jose Abol Correa; Giuseppe Lippi
Journal:  J Med Biochem       Date:  2017-01-25       Impact factor: 3.402

Review 8.  Preanalytical investigations of phlebotomy: methodological aspects, pitfalls and recommendations.

Authors:  Cristiano Ialongo; Sergio Bernardini
Journal:  Biochem Med (Zagreb)       Date:  2017-02-15       Impact factor: 2.313

9.  The effective reduction of tourniquet application time after minor modification of the CLSI H03-A6 blood collection procedure.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

10.  Specimen rejection in laboratory medicine: Necessary for patient safety?

Authors:  Zeliha Gunnur Dikmen; Asli Pinar; Filiz Akbiyik
Journal:  Biochem Med (Zagreb)       Date:  2015-10-15       Impact factor: 2.313

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.