Literature DB >> 21899247

Comparison of complication rates of porous anophthalmic orbital implants.

Nicholas Ramey1, Divakar Gupta, Kristina Price, Amina Husain, Michael Richard, Julie Woodward.   

Abstract

BACKGROUND AND
OBJECTIVE: Porous anophthalmic orbital implants are used widely. This study evaluates risk factors for porous anophthalmic orbital implant complications and compares complication rates of hydroxyapatite, porous polyethylene, and polyglactin mesh-wrapped aluminum oxide implants. PATIENTS AND METHODS: The records of 105 patients (110 eyes) who received porous anophthalmic orbital implants for any indication were reviewed retrospectively. Complications were recorded and correlated with potential risk factors, including implant material. All patient records were de-identified to protect privacy.
RESULTS: Porous polyethylene and aluminum oxide implants were associated with higher exposure rates (porous polyethylene: odds ratio 6.1 [1.29, 29.1]; aluminum oxide: odds ratio 6.0 [1.58, 23.1]; P = .004) and higher overall complication rates compared to hydroxyapatite implants.
CONCLUSION: Implant material may be a risk factor for several anophthalmic clinical outcomes. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21899247     DOI: 10.3928/15428877-20110812-03

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging        ISSN: 1542-8877


  5 in total

1.  Indications and results in anophthalmic socket reconstruction using dermis-fat graft.

Authors:  Orapan Aryasit; Passorn Preechawai
Journal:  Clin Ophthalmol       Date:  2015-05-04

2.  Complications of orbital endoimplantation in the Eye Clinic of the Lithuanian University of Health Sciences.

Authors:  Raimonda Piškinienė; Mantas Banevičius
Journal:  Acta Med Litu       Date:  2017

Review 3.  Ocular implants-methods of ocular reconstruction following radical surgical interventions.

Authors:  Corina Teodora Catalu; Sânziana Luminiţa Istrate; Liliana Mary Voinea; Costin Mitulescu; Viorela Popescu; Ciuluvică Radu
Journal:  Rom J Ophthalmol       Date:  2018 Jan-Mar

4.  Copper-Doped Bioactive Glass/Poly (Ether-Ether-Ketone) Composite as an Orbital Enucleation Implant in a Rabbit Model: An In Vivo Study.

Authors:  Ke Xiong; Mengen Zhao; Zhaoying Wu; Wei Zhang; Chao Zhang
Journal:  Materials (Basel)       Date:  2022-06-22       Impact factor: 3.748

5.  Use of extraocular muscle flaps in the correction of orbital implant exposure.

Authors:  Hsueh-Yen Chu; Yi-Lin Liao; Yueh-Ju Tsai; Yen-Chang Chu; Shu-Ya Wu; Lih Ma
Journal:  PLoS One       Date:  2013-09-25       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.