Literature DB >> 21897974

Fungal DNA in hotel rooms in Europe and Asia--associations with latitude, precipitation, building data, room characteristics and hotel ranking.

Dan Norbäck1, Gui-Hong Cai.   

Abstract

There is little information on the indoor environment in hotels. Analysis of fungal DNA by quantitative PCR (qPCR) is a new method which can detect general and specific sequences. Dust was collected through swab sampling of door frames in 69 hotel rooms in 20 countries in Europe and Asia (2007-2009). Five sequences were detected by qPCR: total fungal DNA, Aspergillus and Penicillium DNA (Asp/Pen DNA), Aspergillus versicolor (A. versicolor DNA), Stachybotrys chartarum (S. chartarum DNA) and Streptomyces spp. (Streptomyces DNA). Associations were analysed by multiple linear regression. Total fungal DNA (GM = 1.08 × 10(8) cell equivalents m(-2); GSD = 6.36) and Asp/Pen DNA (GM = 1.79 × 10(7) cell equivalents m(-2); GSD = 10.12) were detected in all rooms. A. versicolor DNA, S. chartarum DNA and Streptomyces DNA were detected in 84%, 28% and 47% of the samples. In total, 20% of the rooms had observed dampness/mould, and 30% had odour. Low latitude (range 1.5-64.2 degrees) was a predictor of Asp/Pen DNA. Seaside location, lack of mechanical ventilation, and dampness or mould were other predictors of total fungal DNA and Asp/Pen DNA. Hotel ranking (Trip Advisor) or self-rated quality of the interior of the hotel room was a predictor of total fungal DNA, A. versicolor DNA and Streptomyces DNA. Odour was a predictor of S. chartarum DNA. In conclusion, fungal DNA in swab samples from hotel rooms was related to latitude, seaside location, ventilation, visible dampness and indoor mould growth. Hotels in tropical areas may have 10-100 times higher levels of common moulds such as Aspergillus and Penicillium species, as compared to a temperate climate zone.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21897974     DOI: 10.1039/c1em10439j

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  6 in total

1.  Fungal DNA in dust in Swedish day care centres: associations with respiratory symptoms, fractional exhaled nitrogen oxide (FeNO) and C-reactive protein (CRP) in serum among day care centre staff.

Authors:  Dan Norbäck; Gui-Hong Cai; Ivan Kreft; Erik Lampa; Gunilla Wieslander
Journal:  Int Arch Occup Environ Health       Date:  2015-07-17       Impact factor: 3.015

2.  Fungal pollution of indoor environments and its management.

Authors:  A A Haleem Khan; S Mohan Karuppayil
Journal:  Saudi J Biol Sci       Date:  2012-06-15       Impact factor: 4.219

3.  Continental-Scale Microbiome Study Reveals Different Environmental Characteristics Determining Microbial Richness, Composition, and Quantity in Hotel Rooms.

Authors:  Yanling Li; Qianqian Yuan; Xi Fu; Gui-Hong Cai; Yiqun Deng; Xin Zhang; Dan Norbäck; Yu Sun
Journal:  mSystems       Date:  2020-05-19       Impact factor: 6.496

4.  Indoor Air Design Parameters of Air Conditioners for Mold-Prevention and Antibacterial in Island Residential Buildings.

Authors:  Xueyan Zhang; Jingyi Liang; Beibei Wang; Yang Lv; Jingchao Xie
Journal:  Int J Environ Res Public Health       Date:  2020-10-07       Impact factor: 3.390

5.  Endotoxin, ergosterol, fungal DNA and allergens in dust from schools in Johor Bahru, Malaysia- associations with asthma and respiratory infections in pupils.

Authors:  Dan Norbäck; Pawel Markowicz; Gui-Hong Cai; Zailina Hashim; Faridah Ali; Yi-Wu Zheng; Xu-Xin Lai; Michael Dho Spangfort; Lennart Larsson; Jamal Hisham Hashim
Journal:  PLoS One       Date:  2014-02-11       Impact factor: 3.240

6.  Rhinitis, Ocular, Throat and Dermal Symptoms, Headache and Tiredness among Students in Schools from Johor Bahru, Malaysia: Associations with Fungal DNA and Mycotoxins in Classroom Dust.

Authors:  Dan Norbäck; Jamal Hisham Hashim; Gui-Hong Cai; Zailina Hashim; Faridah Ali; Erica Bloom; Lennart Larsson
Journal:  PLoS One       Date:  2016-02-01       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.