Literature DB >> 21897345

Reliability of clinical measurement for assessing spinal fusion: an experimental sheep study.

Sadahiro Sugiyama1, Martin Wullschleger, Kathleen Wilson, Richard Williams, Ben Goss.   

Abstract

STUDY
DESIGN: A sheep study designed to compare the accuracy of static radiographs, dynamic radiographs, and computed tomographic (CT) scans for the assessment of thoracolumbar facet joint fusion as determined by micro-CT scanning.
OBJECTIVE: To determine the accuracy and reliability of conventional imaging techniques in identifying the status of thoracolumbar (T13-L1) facet joint fusion in a sheep model. SUMMARY OF BACKGROUND DATA: Plain radiographs are commonly used to determine the integrity of surgical arthrodesis of the thoracolumbar spine. Many previous studies of fusion success have relied solely on postoperative assessment of plain radiographs, a technique lacking sensitivity for pseudarthrosis. CT may be a more reliable technique, but is less well characterized.
METHODS: Eleven adult sheep were randomized to either attempted arthrodesis using autogenous bone graft and internal fixation (n = 3) or intentional pseudarthrosis (IP) using oxidized cellulose and internal fixation (n = 8). After 6 months, facet joint fusion was assessed by independent observers, using (1) plain static radiography alone, (2) additional dynamic radiographs, and (3) additional reconstructed spiral CT imaging. These assessments were correlated with high-resolution micro-CT imaging to predict the utility of the conventional imaging techniques in the estimation of fusion success.
RESULTS: The capacity of plain radiography alone to correctly predict fusion or pseudarthrosis was 43% and was not improved using plain radiography and dynamic radiography with also a 43% accuracy. Adding assessment by reformatted CT imaging to the plain radiography techniques increased the capacity to predict fusion outcome to 86% correctly. The sensitivity, specificity, and accuracy of static radiography were 0.33, 0.55, and 0.43, respectively, those of dynamic radiography were 0.46, 0.40, and 0.43, respectively, and those of radiography plus CT were 0.88, 0.85, and 0.86, respectively.
CONCLUSION: CT-based evaluation correlated most closely with high-resolution micro-CT imaging. Neither plain static nor dynamic radiographs were able to predict fusion outcome accurately.

Entities:  

Mesh:

Year:  2012        PMID: 21897345     DOI: 10.1097/BRS.0b013e31822ffa05

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  8 in total

Review 1.  A systematic review of comparative studies on bone graft alternatives for common spine fusion procedures.

Authors:  Charla R Fischer; Ryan Cassilly; Winifred Cantor; Emmanuel Edusei; Qusai Hammouri; Thomas Errico
Journal:  Eur Spine J       Date:  2013-02-26       Impact factor: 3.134

Review 2.  An analysis of spine fusion outcomes in sheep pre-clinical models.

Authors:  Emily M Lindley; Cameron Barton; Thomas Blount; Evalina L Burger; Christopher M J Cain; Howard B Seim; A Simon Turner; Vikas V Patel
Journal:  Eur Spine J       Date:  2016-05-10       Impact factor: 3.134

3.  Comparison of structural allograft and traditional autograft technique in occipitocervical fusion: radiological and clinical outcomes from a single institution.

Authors:  Jakub Godzik; Vijay M Ravindra; Wilson Z Ray; Meic H Schmidt; Erica F Bisson; Andrew T Dailey
Journal:  J Neurosurg Spine       Date:  2015-05-08

4.  Autogenic Rib Graft for Atlantoaxial and Occipitocervical Fixation in Pediatric Patients.

Authors:  Akira Matsumura; Takashi Namikawa; Minori Kato; Yusuke Hori; Masayoshi Iwamae; Noriaki Hidaka; Sadahiko Konishi; Hiroaki Nakamura
Journal:  Asian Spine J       Date:  2019-05-14

Review 5.  The efficacy of platelet-rich plasma applicated in spinal fusion surgery: A meta-analysis.

Authors:  Hongwei Yu; Zhaohong Zhou; Bin Yu; Tianwei Sun; Qiong Tang; Yutao Jia
Journal:  Front Surg       Date:  2022-09-23

6.  Spinal Motion and Muscle Activity during Active Trunk Movements - Comparing Sheep and Humans Adopting Upright and Quadrupedal Postures.

Authors:  Stephanie Valentin; Theresia F Licka
Journal:  PLoS One       Date:  2016-01-07       Impact factor: 3.240

7.  Evaluation of Spinal Fusion in Thoracic and Thoracolumbar Spine on Standard X-Rays: A New Grading System for Spinal Interbody Fusion.

Authors:  Nirmal D Patil; Hussein Abou El Ghait; Christian Boehm; Heinrich Boehm
Journal:  Global Spine J       Date:  2021-02-15

8.  Risk Factors of Nonunion After Acute Osteoporotic Vertebral Fractures: A Prospective Multicenter Cohort Study.

Authors:  Hiroyuki Inose; Tsuyoshi Kato; Shoichi Ichimura; Hiroaki Nakamura; Masatoshi Hoshino; Daisuke Togawa; Toru Hirano; Yasuaki Tokuhashi; Tetsuro Ohba; Hirotaka Haro; Takashi Tsuji; Kimiaki Sato; Yutaka Sasao; Masahiko Takahata; Koji Otani; Suketaka Momoshima; Masato Yuasa; Takashi Hirai; Toshitaka Yoshii; Atsushi Okawa
Journal:  Spine (Phila Pa 1976)       Date:  2020-07-01       Impact factor: 3.241

  8 in total