We compared the surface free-energies and dentin bond strengths of single-step self-etch adhesives with and without an oxygen-inhibited layer. The labial dentin surfaces of bovine mandibular incisors were wet ground with #600-grit silicon carbide paper. The adhesives were applied to the ground dentin, light-irradiated, and the oxygen-inhibited layer was either retained or removed with ethanol. The surface free-energies were determined by measuring the contact angles of three test liquids placed on the cured adhesives. The dentin bond strengths of specimens with and without the oxygen-inhibited layer were measured. For all surfaces, the value of the estimated surface tension component was relatively constant at 35.5-39.8 mJ m(-2) . The value of the , Lewis acid component increased slightly when the oxygen-inhibited layer was removed, whereas that of the , Lewis base component decreased significantly. The bond strengths of the self-etch adhesives were significantly lower in specimens without an oxygen-inhibited layer (13.2-13.6 MPa) than in those with an oxygen-inhibited layer (17.5-18.4 MPa). These results indicate that the presence of an oxygen-inhibited layer in single-step self-etch adhesives with advanced photoinitiators promotes higher dentin bond strength.Entities: