Literature DB >> 2189448

Estimating anesthetic depth by electroencephalography during anesthetic induction and intubation in patients undergoing cardiac surgery.

A Sidi1, P Halimi, S Cotev.   

Abstract

Intravenous (IV) anesthesia titrated to continuous computer-processed electroencephalograms (EEGs) was studied in 32 consecutive patients undergoing cardiac surgery. Anesthesia was induced with fentanyl 50 micrograms/kg with no EEG monitoring (n = 16) or 25 to 50 micrograms depending on changes in EEG (n = 16). EEG, oxygen saturation by pulse oximeter, intra-arterial blood pressure (BP), central venous pressure (CVP), and pulmonary artery pressure (PAP) (n = 18) were monitored continuously. Cardiac output (CO), CVP, PAP, spectral-edge frequency for each hemisphere, and BP were recorded before induction, immediately before intubation, and 1 and 5 minutes after intubation. With EEG monitoring, intubation was performed when spectral-edge frequency decreased to 10 Hz or less. Recall and pain were investigated 2 to 12 weeks postoperatively. With EEG, the amount of fentanyl used before intubation was significantly lower (39.7 +/- 2 micrograms/kg; p less than 0.005) than without EEG (50 micrograms/kg). The decrease in BP (% change) was less with than without EEG; mean changes in BP between preinduction and preintubation were -7.4% +/- 3.8% and -16.5% +/- 3.1% and between preinduction and 1 minute after intubation 0.3% +/- 3.4% and -12.5% +/- 3.5%, respectively. Percent changes in mean BP between intubation and 1 minute after were 9.6% +/- 4.0% with EEG and 5.2% +/- 3.0% without EEG. No patient in either group had recall. The authors conclude that using EEG monitoring to estimate depth of anesthesia during induction and laryngoscopy may increase safety in high-risk patients undergoing cardiac surgery.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2189448     DOI: 10.1016/0952-8180(90)90062-8

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  5 in total

Review 1.  Using EEG to monitor anesthesia drug effects during surgery.

Authors:  Leslie C Jameson; Tod B Sloan
Journal:  J Clin Monit Comput       Date:  2006-12       Impact factor: 2.502

2.  Application of semilinear canonical correlation to the measurement of opioid drug effect.

Authors:  K M Gregg; J R Varvel; S L Shafer
Journal:  J Pharmacokinet Biopharm       Date:  1992-12

3.  Time-frequency spectral representation of the EEG as an aid in the detection of depth of anesthesia.

Authors:  A Nayak; R J Roy; A Sharma
Journal:  Ann Biomed Eng       Date:  1994 Sep-Oct       Impact factor: 3.934

4.  EEG bispectrum predicts movement during thiopental/isoflurane anesthesia.

Authors:  P S Sebel; S M Bowles; V Saini; N Chamoun
Journal:  J Clin Monit       Date:  1995-03

Review 5.  Anaesthetic interventions for prevention of awareness during surgery.

Authors:  Anthony G Messina; Michael Wang; Marshall J Ward; Chase C Wilker; Brett B Smith; Daniel P Vezina; Nathan Leon Pace
Journal:  Cochrane Database Syst Rev       Date:  2016-10-18