Literature DB >> 21892112

Tear menisci after overnight contact lens wear.

Aizhu Tao1, Chunyan Cai, Meixiao Shen, Jianhua Wang, Zhao Chen, Suzhong Xu, Ming Li, Fan Lu.   

Abstract

PURPOSE: To determine the effect of overnight wear of contact lenses (CL) on tear meniscus, tear film stability, and subjective comfort.
METHODS: Sixty asymptomatic subjects were divided into three groups. The control group was composed of 20 non-CL wearers. Twenty inexperienced and 20 experienced CL wearers were enrolled as group 1 and group 2. For each subject in groups 1 and 2, a hydrogel and a silicone hydrogel CL were randomly assigned to each eye. Optical coherence tomography was used to determine volumes of the upper and lower tear menisci. Tear film stability was determined by non-invasive tear break-up time (NITBUT) measured by tearscope. A previously used questionnaire assessed dry eye symptoms. Subjects were evaluated during an 11-h period, including immediately before and after sleeping.
RESULTS: Compared with the presleep levels, tear meniscus volume in the control group increased immediately after awakening and recovered by 1 hour later (p < 0.05). In contrast, tear meniscus volume in lens wearers increased on eye opening and recovered by 10 min later (p < 0.05). Tear meniscus volumes in CL wearers were less than those in controls at eye opening. NITBUT and comfort scores decreased immediately after CL insertion (p = 0.00). After eye opening, NITBUT was larger than the presleep levels until 10 min later. The comfort score was lower than the presleep values until 5 min later.
CONCLUSIONS: Dynamic changes in the tear menisci, NITBUT, and comfort level were evident in both inexperienced and experienced CL wearers during and after overnight wear. Decreased tear meniscus volumes and tear film stability may contribute to lower eye comfort for extended CL wearers. The tearing on eye opening may facilitate improvement of ocular comfort and tear refreshment for a reconditioning of the tear system and the CL.

Entities:  

Mesh:

Year:  2011        PMID: 21892112     DOI: 10.1097/OPX.0b013e3182303631

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  1 in total

1.  Tracking the Reflective Light Particles Spreading on the Cornea: An Emerging Assessment for Tear Film Homeostasis.

Authors:  Hung-Yin Lai; Ming-Tse Kuo; Po-Chiung Fang; Chi-Chang Lin; Chun-Chih Chien; Wan-Hua Cho; Alexander Chen; Ing-Chou Lai
Journal:  Transl Vis Sci Technol       Date:  2019-06-04       Impact factor: 3.283

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.