Literature DB >> 21890886

Maternal cardiac output changes after crystalloid or colloid coload following spinal anesthesia for elective cesarean delivery: a randomized controlled trial.

Sarah McDonald1, Roshan Fernando, Keri Ashpole, Malachy Columb.   

Abstract

BACKGROUND: Minimizing hypotension associated with spinal anesthesia for cesarean delivery by administration of IV fluids and vasopressors reduces fetal and maternal morbidity. Most studies have concentrated on noninvasive systolic blood pressure (SBP) measurements to evaluate the effect of such regimens. We used a suprasternal Doppler flow technique to measure maternal cardiac output (CO) variables in parturients receiving a phenylephrine infusion combined with the rapid administration of crystalloid or colloid solution at the time of initiation of anesthesia (coload). We hypothesized that a colloid coload compared with a crystalloid coload would produce a larger sustained increase in CO and therefore reduce vasopressor requirements.
METHODS: We recruited 60 healthy term women scheduled for elective cesarean delivery under spinal anesthesia for this randomized double-blind study. Baseline heart rate, baseline SBP, and CO variables including stroke volume, corrected flow time, and contractility were recorded in the left lateral tilt position. At the time of spinal injection, subjects were allocated to receive a rapid 1-L coload of either 6% w/v hydroxyethyl starch solution (HES) or Hartmann (crystalloid) solution (HS). A phenylephrine infusion was titrated to maintain maternal baseline SBP. CO was measured at 5-minute intervals for 20 minutes after initiation of spinal anesthesia. The primary outcome, CO, was compared between groups, as were secondary outcomes: phenylephrine dose and maternal hemodynamic and fetal outcome data.
RESULTS: Maternal demographics, surgical times, and fetal outcome data were similar between groups. There were no significant differences between groups in any measured CO variable at any time point. CO was transiently higher than baseline at 5 minutes in the HS group and at 5 and 10 minutes in the HES group (range, 0.13-1.74 L/min); the overall mean difference in CO between crystalloid and colloid over the study period was 0.06 L/min (95% confidence interval: -0.46 to 0.58). Stroke volume was higher than baseline in both groups throughout; peak velocity was consistently higher than baseline only in the HES group; and corrected flow time increased in both groups; the effect was transient in the HS but sustained in the HES group. Heart rate was not different at any time point within or between groups but did decrease over time. The total phenylephrine dose from time of spinal anesthesia to delivery was similar between groups.
CONCLUSION: We found no difference in CO in women randomized to colloid or crystalloid coload. In addition, there were no differences in vasopressor requirements or hemodynamic stability. We conclude that there is no advantage in using colloid over crystalloid when used in combination with a phenylephrine infusion during spinal anesthesia for elective cesarean delivery.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21890886     DOI: 10.1213/ANE.0b013e31822c0f08

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  18 in total

1.  The effect of 0.5 L 6% hydroxyethyl starch 130/0.42 versus 1 L Ringer's lactate preload on the hemodynamic status of parturients undergoing spinal anesthesia for elective cesarean delivery using arterial pulse contour analysis.

Authors:  Paraskevi Matsota; Agathi Karakosta; Ageliki Pandazi; Dimitra Niokou; Kalliopi Christodoulaki; Georgia Kostopanagiotou
Journal:  J Anesth       Date:  2014-09-30       Impact factor: 2.078

Review 2.  [Comments on the updated German S3 guidelines on intravascular volume therapy in adults].

Authors:  Emmanuel Schneck; Michael Sander; Bernd Saugel; Daniel A Reuter; Marit Habicher
Journal:  Anaesthesist       Date:  2021-03-01       Impact factor: 1.041

3.  Role of cerebral oxygenation for prediction of hypotension after spinal anesthesia for caesarean section.

Authors:  Shen Sun; Nai-He Liu; Shao-Qiang Huang
Journal:  J Clin Monit Comput       Date:  2015-07-18       Impact factor: 2.502

4.  Patient blood management in obstetrics: prevention and treatment of postpartum haemorrhage. A NATA consensus statement.

Authors:  Manuel Muñoz; Jakob Stensballe; Anne-Sophie Ducloy-Bouthors; Marie-Pierre Bonnet; Edoardo De Robertis; Ino Fornet; François Goffinet; Stefan Hofer; Wolfgang Holzgreve; Susana Manrique; Jacky Nizard; François Christory; Charles-Marc Samama; Jean-François Hardy
Journal:  Blood Transfus       Date:  2019-02-06       Impact factor: 3.443

5.  Effects of hydroxyethyl starch 6 % (130/0.4) on blood loss during cesarean delivery: a propensity-matched analysis.

Authors:  Abdullah S Terkawi; Sarah K Larkin; Siny Tsang; Jessica S Sheeran; Mohamed Tiouririne
Journal:  J Anesth       Date:  2016-06-30       Impact factor: 2.078

6.  Low molecular weight pentastarch is more effective than crystalloid solution in goal-directed fluid management in patients undergoing major gastrointestinal surgery.

Authors:  Yoshifumi Kotake; Mitsue Fukuda; Aya Yamagata; Ririko Iwasaki; Daisuke Toyoda; Nobukazu Sato; Ryoichi Ochiai
Journal:  J Anesth       Date:  2013-09-06       Impact factor: 2.078

7.  Techniques for preventing hypotension during spinal anaesthesia for caesarean section.

Authors:  Cheryl Chooi; Julia J Cox; Richard S Lumb; Philippa Middleton; Mark Chemali; Richard S Emmett; Scott W Simmons; Allan M Cyna
Journal:  Cochrane Database Syst Rev       Date:  2020-07-01

Review 8.  Hydroxyeyhyl starch: Controversies revisited.

Authors:  Rashmi Datta; Rajeev Nair; Anil Pandey; Nitish Gupta; Tapan Sahoo
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2014-10

9.  Colloid cohydration and variable rate phenylephrine infusion effectively prevents postspinal hypotension in elective Cesarean deliveries.

Authors:  Indu Sen; Rozeeta Hirachan; Neerja Bhardwaj; Kajal Jain; Vanita Suri; Praveen Kumar
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-07

10.  Comparison of the effects of pre-anesthetic administration of normal saline, ringer and voluven on the spread of sensory block with hyperbaric bupivacaine spinal anesthesia.

Authors:  Elham Memary; Alireza Mirkheshti; Morteza Jabbari Moghaddam; Dariush Abtahi; Mehdi Yaseri; Farnaz Kamali
Journal:  Anesth Pain Med       Date:  2014-05-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.