Literature DB >> 21885703

The effect of drill bit, pin, and wire tip design on drilling.

Bryce M Fincham1, Todd Jaeblon.   

Abstract

Successful penetration of bone is dependent on several factors, including bone quality, drill bit and pin design, and drilling technique. Wires are also used in bone drilling, and the tip configuration can affect the efficiency of bone penetration. Incorrect use of drill bits, pins, and wires may result in complications such as thermal necrosis and hardware breakage.

Entities:  

Mesh:

Year:  2011        PMID: 21885703     DOI: 10.5435/00124635-201109000-00008

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


  7 in total

1.  Temperature changes and chondrocyte death during drilling in a bovine cartilage model and chondroprotection by modified irrigation solutions.

Authors:  Muhamed M H Farhan-Alanie; Andrew C Hall
Journal:  Int Orthop       Date:  2014-05-24       Impact factor: 3.075

2.  Percutaneous electrode placement for spinal cord stimulation in a patient with spinal fusion: a technical report.

Authors:  Sung-Chun Park; Kyung-Hoon Kim
Journal:  J Anesth       Date:  2012-01-04       Impact factor: 2.078

Review 3.  Surgical Drill Bit Design and Thermomechanical Damage in Bone Drilling: A Review.

Authors:  Mohd Faizal Ali Akhbar; Akmal Wani Sulong
Journal:  Ann Biomed Eng       Date:  2020-08-28       Impact factor: 3.934

4.  Biomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: an Animal in Vitro Study.

Authors:  Mohammad Javad Ein-Afshar; Mostafa Shahrezaee; Mohammad Hossein Shahrezaee; Seyed Reza Sharifzadeh
Journal:  Arch Bone Jt Surg       Date:  2020-09

5.  Kirschner wire prepared pilot holes improve screw pullout strength in synthetic osteoporotic-type bone.

Authors:  Hrayr G Basmajian; Joseph N Liu; Travis Scudday; Seth T Campbell; Nirav H Amin
Journal:  J Clin Orthop Trauma       Date:  2019-08-22

6.  Thermal damage during humeral reaming in total shoulder resurfacing.

Authors:  Philip A McCann; Partha P Sarangi; Richard P Baker; Ashley W Blom; Rouin Amirfeyz
Journal:  Int J Shoulder Surg       Date:  2013-07

Review 7.  Subchondral drilling for articular cartilage repair: a systematic review of translational research.

Authors:  Liang Gao; Lars K H Goebel; Patrick Orth; Magali Cucchiarini; Henning Madry
Journal:  Dis Model Mech       Date:  2018-06-19       Impact factor: 5.758

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.