Literature DB >> 21885150

First pilot trial of the STAR-Liege protocol for tight glycemic control in critically ill patients.

Sophie Penning1, Aaron J Le Compte, Katherine T Moorhead, Thomas Desaive, Paul Massion, Jean-Charles Preiser, Geoffrey M Shaw, J Geoffrey Chase.   

Abstract

Tight glycemic control (TGC) has shown benefits in ICU patients, but been difficult to achieve consistently due to inter- and intra- patient variability that requires more adaptive, patient-specific solutions. STAR (Stochastic TARgeted) is a flexible model-based TGC framework accounting for patient variability with a stochastically derived maximum 5% risk of blood glucose (BG) below 72 mg/dL. This research describes the first clinical pilot trial of the STAR approach and the post-trial analysis of the models and methods that underpin the protocol. The STAR framework works with clinically specified targets and intervention guidelines. The clinically specified glycemic target was 125 mg/dL. Each trial was 24 h with BG measured 1-2 hourly. Two-hourly measurement was used when BG was between 110-135 mg/dL for 3 h. In the STAR approach, each intervention leads to a predicted BG level and outcome range (5-95th percentile) based on a stochastic model of metabolic patient variability. Carbohydrate intake (all sources) was monitored, but not changed from clinical settings except to prevent BG<100 mg/dL when no insulin was given. Insulin infusion rates were limited (6 U/h maximum), with limited increases based on current infusion rate (0.5-2.0 U/h), making this use of the STAR framework an insulin-only TGC approach. Approval was granted by the Ethics Committee of the Medical Faculty of the University of Liege (Liege, Belgium). Nine patient trials were undertaken after obtaining informed consent. There were 205 measurements over all 9 trials. Median [IQR] per-patient results were: BG: 138.5 [130.6-146.0]mg/dL; carbohydrate administered: 2-11 g/h; median insulin:1.3 [0.9-2.4]U/h with a maximum of 6.0 [4.7-6.0]U/h. Median [IQR] time in the desired 110-140 mg/dL band was: 50.0 [31.2-54.2]%. Median model prediction errors ranged: 10-18%, with larger errors due to small meals and other clinical events. The minimum BG was 63 mg/dL and no other measurement was below 72 mg/dL, so only 1 measurement (0.5%) was below the 5% guaranteed minimum risk level. Post-trial analysis showed that patients were more variable than predicted by the stochastic model used for control, resulting in some of the prediction errors seen. Analysis and (validated) virtual trial re-simulating the clinical trial using stochastic models relevant to the patient's particular day of ICU stay were seen to be more accurate in capturing the observed variability. This analysis indicated that equivalent control and safety could be obtained with similar or lower glycemic variability in control using more specific stochastic models. STAR effectively controlled all patients to target. Observed patient variability in response to insulin and thus prediction errors were higher than expected, likely due to the recent insult of cardiac surgery or a major cardiac event, and their immediate recovery. STAR effectively managed this variability with no hypoglycemia. Improved stochastic models will be used to prospectively test these outcomes in further ongoing clinical pilot trials in this and other units.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21885150     DOI: 10.1016/j.cmpb.2011.07.003

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  10 in total

1.  Stochastic targeted (STAR) glycemic control: design, safety, and performance.

Authors:  Alicia Evans; Aaron Le Compte; Chia-Siong Tan; Logan Ward; James Steel; Christopher G Pretty; Sophie Penning; Fatanah Suhaimi; Geoffrey M Shaw; Thomas Desaive; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2012-01-01

2.  Interface design and human factors considerations for model-based tight glycemic control in critical care.

Authors:  Logan Ward; James Steel; Aaron Le Compte; Alicia Evans; Chia-Siong Tan; Sophie Penning; Geoffrey M Shaw; Thomas Desaive; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2012-01-01

3.  Data entry errors and design for model-based tight glycemic control in critical care.

Authors:  Logan Ward; James Steel; Aaron Le Compte; Alicia Evans; Chia-Siong Tan; Sophie Penning; Geoffrey M Shaw; Thomas Desaive; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2012-01-01

Review 4.  The future is now: software-guided intensive insulin therapy in the critically ill.

Authors:  Rishi Rattan; Stanley A Nasraway
Journal:  J Diabetes Sci Technol       Date:  2013-03-01

5.  Pilot study of the SPRINT glycemic control protocol in a Hungarian medical intensive care unit.

Authors:  Balazs Benyo; Attila Illyés; Noémi Szabó Némedi; Aaron J Le Compte; Attila Havas; Levente Kovacs; Liam Fisk; Geoffrey M Shaw; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

6.  Assessment of Glycemic Control Protocol (STAR) Through Compliance Analysis Amongst Malaysian ICU Patients.

Authors:  Athirah Abdul Razak; Asma Abu-Samah; Normy Norfiza Abdul Razak; Ummu Jamaludin; Fatanah Suhaimi; Azrina Ralib; Mohd Basri Mat Nor; Christopher Pretty; Jennifer Laura Knopp; James Geoffrey Chase
Journal:  Med Devices (Auckl)       Date:  2020-06-04

7.  Pilot proof of concept clinical trials of Stochastic Targeted (STAR) glycemic control.

Authors:  Alicia Evans; Geoffrey M Shaw; Aaron Le Compte; Chia-Siong Tan; Logan Ward; James Steel; Christopher G Pretty; Leesa Pfeifer; Sophie Penning; Fatanah Suhaimi; Matthew Signal; Thomas Desaive; J Geoffrey Chase
Journal:  Ann Intensive Care       Date:  2011-09-19       Impact factor: 6.925

8.  Impact of Haemodialysis on Insulin Kinetics of Acute Kidney Injury Patients in Critical Care.

Authors:  Ummu K Jamaludin; Paul D Docherty; J Geoffrey Chase; Geoffrey M Shaw
Journal:  J Med Biol Eng       Date:  2015-02-03       Impact factor: 1.553

Review 9.  The benefits of tight glycemic control in critical illness: Sweeter than assumed?

Authors:  Andrew John Gardner
Journal:  Indian J Crit Care Med       Date:  2014-12

10.  Second pilot trials of the STAR-Liege protocol for tight glycemic control in critically ill patients.

Authors:  Sophie Penning; Aaron J Le Compte; Paul Massion; Katherine T Moorhead; Christopher G Pretty; Jean-Charles Preiser; Geoffrey M Shaw; Fatanah Suhaimi; Thomas Desaive; J Geoffrey Chase
Journal:  Biomed Eng Online       Date:  2012-08-23       Impact factor: 2.819

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.