Literature DB >> 21883463

Mechanical circulatory support as a bridge to transplant candidacy.

Abdelsalam M Elhenawy1, Khaled D Algarni, Marnie Rodger, Jane Maciver, Manjula Maganti, Robert J Cusimano, Terrence M Yau, Diego H Delgado, Heather J Ross, Vivek Rao.   

Abstract

INTRODUCTION: The use of mechanical circulatory support (MCS) in nontransplant eligible candidates remains controversial. Our decision to offer MCS for nontransplant candidates has led to their reevaluation after a period of left ventricular assist device (LVAD) support.
METHODS: From 2001 to September 2009, we had 37 patients who received an implantable LVAD, 22 (59%) were not deemed to be transplant eligible at the time of LVAD insertion (bridge to candidacy, BTC group).
RESULTS: Fifteen (41%) patients were considered transplant eligible (bridge to transplant, BTT group) at the time of device insertion and received a HeartMate XVE (n = 7), HeartMate 2 (n = 7), or a Novacor LVAS (n = 1). In the BTC group, patients received the HeartMate XVE device (n = 11), HeartMate 2 (n = 5), or the Novacor LVAS (n = 6). The primary criterion for transplant ineligibility was refractory pulmonary hypertension (PH) in 18 patients, 3 patients did not meet our body mass index criteria (>35 kg/m(2)), and 2 patients were dialysis-dependent. Six (27%) BTC patients died on support. Overall, 16/22 patients (73%) were subsequently listed for transplantation, with one listed for combined heart-lung due to refractory PH. Twelve patients (75%) underwent successful heart transplantation. Three patients died during their transplant. Overall posttransplant survival at one year shows lower survival in the BTC group compared to the BTT group (67% vs. 100%, p = 0.05). At two years and three years the survival was lower, but not statistically different (BTC vs. BTT: 67% vs. 90% and 64% vs. 87%, respectively, p = NS).
CONCLUSIONS: MCS can successfully convert a large proportion of transplant-ineligible patients into acceptable candidates.
© 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21883463     DOI: 10.1111/j.1540-8191.2011.01310.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  6 in total

1.  Predicting right ventricular failure in the modern, continuous flow left ventricular assist device era.

Authors:  Pavan Atluri; Andrew B Goldstone; Alex S Fairman; John W MacArthur; Yasuhiro Shudo; Jeffrey E Cohen; Alexandra L Acker; William Hiesinger; Jessica L Howard; Michael A Acker; Y Joseph Woo
Journal:  Ann Thorac Surg       Date:  2013-06-21       Impact factor: 4.330

Review 2.  Korean Guidelines for Diagnosis and Management of Chronic Heart Failure.

Authors:  Min-Seok Kim; Ju-Hee Lee; Eung Ju Kim; Dae-Gyun Park; Sung-Ji Park; Jin Joo Park; Mi-Seung Shin; Byung Su Yoo; Jong-Chan Youn; Sang Eun Lee; Sang Hyun Ihm; Se Yong Jang; Sang-Ho Jo; Jae Yeong Cho; Hyun-Jai Cho; Seonghoon Choi; Jin-Oh Choi; Seong Woo Han; Kyung Kuk Hwang; Eun Seok Jeon; Myeong-Chan Cho; Shung Chull Chae; Dong-Ju Choi
Journal:  Korean Circ J       Date:  2017-09-18       Impact factor: 3.243

3.  Exercise guidelines for inpatients following ventricular assist device placement: a systematic review of the literature.

Authors:  Rachel Scheiderer; Courtney Belden; Darla Schwab; Casey Haney; Jaime Paz
Journal:  Cardiopulm Phys Ther J       Date:  2013-06

4.  Continuous flow left ventricular assist device implant significantly improves pulmonary hypertension, right ventricular contractility, and tricuspid valve competence.

Authors:  Pavan Atluri; Alexander S Fairman; John W MacArthur; Andrew B Goldstone; Jeffrey E Cohen; Jessica L Howard; Christyna M Zalewski; Yasuhiro Shudo; Y Joseph Woo
Journal:  J Card Surg       Date:  2013-09-30       Impact factor: 1.620

5.  New developments in the surgical management of end-stage heart failure.

Authors:  Scott Silvestry
Journal:  Mo Med       Date:  2012 Jul-Aug

Review 6.  Left ventricular assist devices: a kidney's perspective.

Authors:  T R Tromp; N de Jonge; J A Joles
Journal:  Heart Fail Rev       Date:  2015-07       Impact factor: 4.214

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.