Literature DB >> 21883435

Patient satisfaction and barriers to initiating real-time continuous glucose monitoring in early pregnancy in women with diabetes.

A L Secher1, A B Madsen, L Ringholm, C Barfred, E Stage, H U Andersen, P Damm, E R Mathiesen.   

Abstract

AIM: To evaluate self-reported satisfaction and barriers to initiating real-time continuous glucose monitoring in early pregnancy among women with pregestational diabetes.
METHODS: Fifty-four women with Type 1 diabetes and 14 women with Type 2 diabetes were offered continuous glucose monitoring for 6 days at median 9 (range 6-14) gestational weeks and were asked to answer a semi-structured questionnaire on patient satisfaction.
RESULTS: Median HbA1c was 49 (range 34-86) mmol/mol) [6.6 (5.3-10.0) %] and duration of diabetes was 12 (0.5-37) years. Continuous glucose monitoring was used for 6 (0.5-7) days, with 43 (65%) women using continuous glucose monitoring for at least 5 days. The women experienced 2.7 (0-12) alarms per 24 h, of which approximately one third was technical alarms and one third disturbed their sleep. Sixteen women (24%) reported discomfort with continuous glucose monitoring during daytime and twelve (18%) during sleep. Many women reported improved diabetes understanding (52%) and would recommend continuous glucose monitoring to others (83%). Twenty-four patients (36%) had continuous glucose monitoring removed earlier than planned ( before the intended 6 days of initial monitoring). Ten women (15%) did not wish to use continuous glucose monitoring again in pregnancy. Main causes behind early removal of continuous glucose monitoring were self-reported skin irritation, technical problems and continuous glucose monitoring inaccuracy. No differences were found in continuous glucose monitoring use, inconvenience or compliance with respect to diabetes type.
CONCLUSIONS: The majority of pregnant women with diabetes found real-time continuous glucose monitoring useful and the intervention was equally tolerated regardless of diabetes type. Nevertheless, continuous glucose monitoring was frequently removed earlier than planned, primarily because of skin irritation, technical problems and inaccuracy.
© 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 21883435     DOI: 10.1111/j.1464-5491.2011.03426.x

Source DB:  PubMed          Journal:  Diabet Med        ISSN: 0742-3071            Impact factor:   4.359


  13 in total

1.  No effect of periodic continuous glucose monitoring on hemoglobin A1c in poorly regulated type 1 patients.

Authors:  Henrik U Andersen; Majbritt Kjelmann; Minna Wittrup; Thomas P Almdal
Journal:  J Diabetes Sci Technol       Date:  2013-05-01

Review 2.  Role of continuous glucose monitoring in the management of diabetic pregnancy.

Authors:  Niranjala M Hewapathirana; Esther O'Sullivan; Helen R Murphy
Journal:  Curr Diab Rep       Date:  2013-02       Impact factor: 4.810

3.  Cutaneous Complications With Continuous or Flash Glucose Monitoring Use: Systematic Review of Trials and Observational Studies.

Authors:  Nurul A Mohd Asarani; Andrew N Reynolds; Sara E Boucher; Martin de Bock; Benjamin J Wheeler
Journal:  J Diabetes Sci Technol       Date:  2019-08-27

4.  Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm.

Authors:  Timothy S Bailey; Anna Chang; Mark Christiansen
Journal:  J Diabetes Sci Technol       Date:  2014-11-03

Review 5.  Assessing Glycemic Control Using CGM for Women with Diabetes in Pregnancy.

Authors:  Grenye O'Malley; Ally Wang; Selassie Ogyaadu; Carol J Levy
Journal:  Curr Diab Rep       Date:  2021-11-04       Impact factor: 4.810

Review 6.  Managing type 1 diabetes mellitus in pregnancy--from planning to breastfeeding.

Authors:  Lene Ringholm; Elisabeth R Mathiesen; Louise Kelstrup; Peter Damm
Journal:  Nat Rev Endocrinol       Date:  2012-09-11       Impact factor: 43.330

Review 7.  Continuous glucose monitoring in type 1 diabetes.

Authors:  Nelly Mauras; Larry Fox; Kimberly Englert; Roy W Beck
Journal:  Endocrine       Date:  2012-08-28       Impact factor: 3.633

8.  Continuous glucose monitoring in pregnancy: we have the technology but not all the answers.

Authors:  Helen R Murphy
Journal:  Diabetes Care       Date:  2013-07       Impact factor: 19.112

9.  The Evolving Role of Short-Term Professional Continuous Glucose Monitoring on Glycemic Control and Hypoglycemia Among Saudi Patients with Type 1 Diabetes: A Prospective Study.

Authors:  Ayman A Al Hayek; Asirvatham A Robert; Mohammed Al Dawish; Rania A Ahmed; Fahad S Al Sabaan
Journal:  Diabetes Ther       Date:  2015-07-05       Impact factor: 2.945

10.  The effect of real-time continuous glucose monitoring in pregnant women with diabetes: a randomized controlled trial.

Authors:  Anna L Secher; Lene Ringholm; Henrik U Andersen; Peter Damm; Elisabeth R Mathiesen
Journal:  Diabetes Care       Date:  2013-01-24       Impact factor: 19.112

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.