Literature DB >> 21882357

On-site adequacy evaluations performed by cytotechnologists: correlation with final interpretations of 5241 image-guided fine-needle aspiration biopsies.

Oname O Burlingame1, Kessé O Kessé, Stuart G Silverman, Edmund S Cibas.   

Abstract

BACKGROUND: Practice patterns regarding on-site assessment of the adequacy of image-guided fine-needle aspiration biopsies (FNABs) vary among laboratories, but in many laboratories primary responsibility rests with the cytotechnologists. On-site evaluation provides feedback on the need for additional passes and facilitates triaging of the specimen for time-sensitive ancillary studies. Prior studies have suggested that cytotechnologists can assess the initially obtained specimens correctly, but they are few in number and limited by small size. The purpose of this study was to assess the frequency with which our cytotechnologists were able to correctly assess specimens as adequate using a large-scale database that included a wide range of image-guided FNABs.
METHODS: The frequency that on-site adequacy assessments of 5241 image-guided FNABs were correct was determined by correlating the cytotechnologists' assessments of adequacy with the final cytologic interpretation. An adequacy assessment was considered correct if the FNAB was ultimately reported as satisfactory and unequivocally benign or malignant. An adequate reading on a case that was ultimately reported as unsatisfactory, atypical, or suspicious was deemed "incorrect." The effect of imaging modality was also analyzed.
RESULTS: Of 5241 FNABs, 2784 (53%) were interpreted as adequate on site. Of these, 2637 (95%) were correctly considered adequate. Of the common biopsy sites sampled, the adequacy assessments for liver FNABs demonstrated the highest frequency for being correctly considered adequate (97%) and those for kidney FNABs showed the lowest (90%). Imaging modality had no effect on accuracy.
CONCLUSIONS: Cytotechnologists are almost always correct when assessing initial FNAB samples as adequate.
Copyright © 2011 American Cancer Society.

Mesh:

Year:  2011        PMID: 21882357     DOI: 10.1002/cncy.20184

Source DB:  PubMed          Journal:  Cancer Cytopathol        ISSN: 1934-662X            Impact factor:   5.284


  12 in total

1.  Improving molecular testing and personalized medicine in non-small-cell lung cancer in Ontario.

Authors:  C Lim; H S Sekhon; J C Cutz; D M Hwang; S Kamel-Reid; R F Carter; G da Cunha Santos; T Waddell; M Binnie; M Patel; N Paul; T Chung; A Brade; R El-Maraghi; C Sit; M S Tsao; N B Leighl
Journal:  Curr Oncol       Date:  2017-04-27       Impact factor: 3.677

2.  Role of rapid on-site evaluation with cyto-histopathological correlation in diagnosis of lung lesion.

Authors:  Smita Chandra; Harish Chandra; Girish Sindhwani
Journal:  J Cytol       Date:  2014 Oct-Dec       Impact factor: 1.000

3.  This 'Rose' Has no Thorns-Diagnostic Utility of 'Rapid On-Site Evaluation' (ROSE) in Fine Needle Aspiration Cytology.

Authors:  Kanchan Kothari; Santosh Tummidi; Mona Agnihotri; Pragati Sathe; Leena Naik
Journal:  Indian J Surg Oncol       Date:  2019-09-12

4.  Diagnosis of lung cancer in small biopsies and cytology: implications of the 2011 International Association for the Study of Lung Cancer/American Thoracic Society/European Respiratory Society classification.

Authors:  William D Travis; Elisabeth Brambilla; Masayuki Noguchi; Andrew G Nicholson; Kim Geisinger; Yasushi Yatabe; Yuichi Ishikawa; Ignacio Wistuba; Douglas B Flieder; Wilbur Franklin; Adi Gazdar; Philip S Hasleton; Douglas W Henderson; Keith M Kerr; Iver Petersen; Victor Roggli; Erik Thunnissen; Ming Tsao
Journal:  Arch Pathol Lab Med       Date:  2012-09-12       Impact factor: 5.534

5.  Telecytology for Rapid On-Site Evaluation: Current Status.

Authors:  Oscar Lin
Journal:  J Am Soc Cytopathol       Date:  2017-10-12

6.  Comparison of Number of Passes and Cytopathological Specimen Adequacy for Thyroid Fine-Needle Aspiration Biopsy in the Absence of an On-Site Pathologist.

Authors:  Taha Yusuf Kuzan; Ceren Canbey Goret
Journal:  Eur Thyroid J       Date:  2019-10-30

7.  Accuracy of rapid on-site evaluation of endobronchial ultrasound guided transbronchial needle aspirates by respiratory registrars in training and medical scientists compared to specialist pathologists-an initial pilot study.

Authors:  Emily Hopkins; David Moffat; Caroline Smith; Michelle Wong; Ian Parkinson; Walter Nespolon; Jennifer Buckseall; Madeline Hill; Hubertus Jersmann; Phan Nguyen
Journal:  J Thorac Dis       Date:  2018-07       Impact factor: 2.895

Review 8.  Cytotechnologists and on-site evaluation of adequacy.

Authors:  Jennifer A Collins; Anna Novak; Syed Z Ali; Matthew T Olson
Journal:  Korean J Pathol       Date:  2013-10-25

9.  Comparison of 1869 thyroid ultrasound-guided fine-needle aspiration biopsies between general surgeons and interventional radiologists.

Authors:  Hilmi Bozkurt; Oktay İrkörücü; Mehmet Aziret; Enver Reyhan; Mehmet Kemal Okuyan
Journal:  Ann Med Surg (Lond)       Date:  2016-08-02

10.  Easily detectable cytomorphological features to evaluate during ROSE for rapid lung cancer diagnosis: from cytology to histology.

Authors:  Sara Ravaioli; Sara Bravaccini; Maria Maddalena Tumedei; Flavio Pironi; Piero Candoli; Maurizio Puccetti
Journal:  Oncotarget       Date:  2017-02-14
View more