Literature DB >> 21879565

Biofouling characteristics and identification of preponderant bacteria at different nutrient levels in batch tests of a recirculating cooling water system.

Fang Liu1, Chao-Cheng Zhao, Lu Xia, Fei Yang, Xin Chang, Yong-Qiang Wang.   

Abstract

Understanding the influence of nutrient levels on biofouling control is an important requirement for management strategies in a recirculating cooling water system. Nutrient limitation may be one way to control biofouling development without increasing biocide dosing. Therefore, this study was carried out to investigate the effects of nutrient levels on biofouling characteristics and to identify the preponderant bacteria in the batch tests with a simulated cooling water system. The biofouling characteristics were assessed by varying the biofoulant mass and the bacteria respiratory activity, which was estimated by measuring oxygen uptake rates. According to the results obtained in nutrient factor experiments, the biofouling could be better controlled at carbon, nitrogen and phosphorus concentrations of 30 mg N/L, 8 mg N/L and 1.0 mg P/L, respectively. Increasing carbon concentrations shortened the biofouling initial growth period and resulted in higher biofoulant mass. The preponderant bacteria strains involved in biofouling under two culture conditions were identified by applying both physiological and biochemical tests and further molecular biology techniques with phylogenetic affiliation analysis. Enterobacter (family Enterobacteriaceae), Staphylococcus (family Micrococcaceae), Bacillus (family Bacillaceae), Proteus (family Enterobacteriaceae), Neisseria (family Neisseriaceae) and Pseudomonas (family Pseudomonadaceae) were dominant in the conditions of lower carbon concentration (30 mg/L). Enterobacter are autotrophs, but the other five bacteria are all heterotrophs. In the conditions of higher carbon concentration (70 mg/L), Klebsiella (family Enterobacteriaceae), Enterobacter and Microbacterium (family Microbacteriaceae) were dominant; Enterobacter and Microbacterium are heterotrophs.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21879565     DOI: 10.1080/09593330.2010.517220

Source DB:  PubMed          Journal:  Environ Technol        ISSN: 0959-3330            Impact factor:   3.247


  3 in total

1.  Antibacterial and anticorrosive properties of CuZnO@RGO waterborne polyurethane coating in circulating cooling water.

Authors:  Guofei Jiang; Xufei Li; Yangli Che; Yan Lv; Fang Liu; Yongqiang Wang; Chaocheng Zhao; Xiaojuan Wang
Journal:  Environ Sci Pollut Res Int       Date:  2019-02-04       Impact factor: 4.223

Review 2.  Biofouling of Polyamide Membranes: Fouling Mechanisms, Current Mitigation and Cleaning Strategies, and Future Prospects.

Authors:  Jane Kucera
Journal:  Membranes (Basel)       Date:  2019-08-30

3.  Bacterial Respiration Used as a Proxy to Evaluate the Bacterial Load in Cooling Towers.

Authors:  Stepan Toman; Bruno Kiilerich; Ian P G Marshall; Klaus Koren
Journal:  Sensors (Basel)       Date:  2020-11-09       Impact factor: 3.576