Literature DB >> 21878818

Outcomes of fornix-based versus limbus-based conjunctival incisions for glaucoma drainage device implant.

Abraham W Suhr1, Michele C Lim, James D Brandt, Juan Carlos Izquierdo, Neil Willits.   

Abstract

PURPOSE: To determine the effect of conjunctival incision location on the long-term efficacy of nonvalved glaucoma drainage devices.
MATERIALS AND METHODS: We conducted a retrospective review of patients ≥18 years of age with uncontrolled glaucoma [intraocular pressure (IOP) ≥18 mm Hg] who underwent glaucoma drainage device implantation. A comparison was made of a limbal-based (LB-BGI) versus fornix-based (FB-BGI) conjunctival flap during placement of a 350-mm Baerveldt glaucoma implant (AMO, Santa Ana, CA) in subjects with at least 1 year of follow-up data. The primary outcome measure was IOP; secondary outcome measures were medication burden, visual acuity, and surgical complications.
RESULTS: One hundred sixty eyes of 147 glaucoma patients were included. Two years after surgery, the IOP in the LB-BGI group was 14.3±5.3 mm Hg and in the FB-BGI group 13.1±4.7 mm Hg (P=0.47). Overall success of IOP control was achieved at the final visit (range 1 to 5 y) in 90% of the LB-BGI group and 87% of the FB-BGI group (P=0.63). The medication burden of the 2 groups at 1 and 2 years after surgery was not statistically significantly different. Worsening of visual acuity by more than 2 lines was not statistically different between the groups 2 years after the surgery and at the final visit (P=0.47, P=0.60, respectively). A greater number of eyes developed endophthalmitis and were more likely to undergo subsequent tube revision in the FB-BGI group, but the differences were not significant.
CONCLUSIONS: Both incision techniques were equally effective in controlling IOP. Each surgical approach has its advantages and this study suggests that either technique may be used safely and effectively.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 21878818     DOI: 10.1097/IJG.0b013e318227a565

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  5 in total

Review 1.  Aqueous shunts for glaucoma.

Authors:  Victoria L Tseng; Anne L Coleman; Melinda Y Chang; Joseph Caprioli
Journal:  Cochrane Database Syst Rev       Date:  2017-07-28

2.  Improving long-term intraocular pressure and visual outcomes in eyes with aniridic glaucoma.

Authors:  Ramanjit Sihota; Harathy Selvan; Kishan Azmira; Tanuj Dada; Ajay Sharma; Amisha Gupta; Ashish Upadhyay
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-07-30       Impact factor: 3.117

3.  Fornix-based versus limbus-based conjunctival flap in trabeculectomy: a quantitative evaluation of the evidence.

Authors:  Wei Wang; Miao He; Minwen Zhou; Xiulan Zhang
Journal:  PLoS One       Date:  2013-12-26       Impact factor: 3.240

4.  European Glaucoma Society Terminology and Guidelines for Glaucoma, 4th Edition - Chapter 3: Treatment principles and options Supported by the EGS Foundation: Part 1: Foreword; Introduction; Glossary; Chapter 3 Treatment principles and options.

Authors: 
Journal:  Br J Ophthalmol       Date:  2017-06       Impact factor: 4.638

5.  The impact of conjunctival flap method and drainage cannula diameter on bleb survival in the rabbit model.

Authors:  Cooper D Rodgers; Alissa M Meyer; Nicole C Rosenberg; Zachary L Lukowski; Jamie L Schaefer; Gina M Martorana; Monica A Levine; Craig A Meyers; Mark B Sherwood
Journal:  PLoS One       Date:  2018-05-24       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.