Literature DB >> 21877786

Adaptive projection method applied to three-dimensional ultrasonic focusing and steering through the ribs.

E Cochard1, J F Aubry, M Tanter, C Prada.   

Abstract

An adaptive projection method for ultrasonic focusing through the rib cage, with minimal energy deposition on the ribs, was evaluated experimentally in 3D geometry. Adaptive projection is based on decomposition of the time-reversal operator (DORT method) and projection on the "noise" subspace. It is shown that 3D implementation of this method is straightforward, and not more time-consuming than 2D. Comparisons are made between adaptive projection, spherical focusing, and a previously proposed time-reversal focusing method, by measuring pressure fields in the focal plane and rib region using the three methods. The ratio of the specific absorption rate at the focus over the one at the ribs was found to be increased by a factor of up to eight, versus spherical emission. Beam steering out of geometric focus was also investigated. For all configurations projecting steered emissions were found to deposit less energy on the ribs than steering time-reversed emissions: thus the non-invasive method presented here is more efficient than state-of-the-art invasive techniques. In fact, this method could be used for real-time treatment, because a single acquisition of back-scattered echoes from the ribs is enough to treat a large volume around the focus, thanks to real time projection of the steered beams.

Mesh:

Year:  2011        PMID: 21877786     DOI: 10.1121/1.3607419

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  3 in total

1.  Deployable ultrasound applicators for endoluminal delivery of volumetric hyperthermia.

Authors:  Muhammad Zubair; Matthew S Adams; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2021-08-10       Impact factor: 3.914

Review 2.  The road to clinical use of high-intensity focused ultrasound for liver cancer: technical and clinical consensus.

Authors:  Jean-Francois Aubry; Kim Butts Pauly; Chrit Moonen; Gail Ter Haar; Mario Ries; Rares Salomir; Sham Sokka; Kevin Michael Sekins; Yerucham Shapira; Fangwei Ye; Heather Huff-Simonin; Matt Eames; Arik Hananel; Neal Kassell; Alessandro Napoli; Joo Ha Hwang; Feng Wu; Lian Zhang; Andreas Melzer; Young-Sun Kim; Wladyslaw M Gedroyc
Journal:  J Ther Ultrasound       Date:  2013-08-01

3.  Calculating the Effect of Ribs on the Focus Quality of a Therapeutic Spherical Random Phased Array.

Authors:  Muhammad Zubair; Robert Dickinson
Journal:  Sensors (Basel)       Date:  2021-02-09       Impact factor: 3.576

  3 in total