PURPOSE: To prospectively evaluate the impact of C-arm CT on radiation exposure to hepatocellular carcinoma (HCC) patients treated by chemoembolization. MATERIALS AND METHODS: Patients with HCC (N = 87) underwent digital subtraction angiography (DSA; control group) or combined C-arm CT/DSA (test group) for chemoembolization. Dose-area product (DAP) and cumulative dose (CD) were measured for guidance and treatment verification. Contrast agent volume and C-arm CT utility were also measured. RESULTS: The marginal DAP increase in the test group was offset by a substantial (50%) decrease in CD from DSA. Use of C-arm CT allowed reduction of DAP and CD from DSA imaging (P = .007 and P = .017). Experienced operators were more efficient in substituting C-arm CT for DSA, resulting in a negligible increase (7.5%) in total DAP for guidance, compared with an increase of 34% for all operators (P = .03). For treatment verification, DAP from C-arm CT exceeded that from DSA, approaching that of conventional CT. The test group used less contrast medium (P = .001), and C-arm CT provided critical or supplemental information in 20% and 17% of patients, respectively. CONCLUSIONS: Routine use of C-arm CT can increase stochastic risk (DAP) but decrease deterministic risk (CD) from DSA. However, the increase in DAP is operator-dependent, thus, with experience, it can be reduced to under 10%. C-arm CT provides information not provided by DSA in 33% of patients, while decreasing the use of iodinated contrast medium. As with all radiation-emitting modalities, C-arm CT should be used judiciously.
PURPOSE: To prospectively evaluate the impact of C-arm CT on radiation exposure to hepatocellular carcinoma (HCC) patients treated by chemoembolization. MATERIALS AND METHODS:Patients with HCC (N = 87) underwent digital subtraction angiography (DSA; control group) or combined C-arm CT/DSA (test group) for chemoembolization. Dose-area product (DAP) and cumulative dose (CD) were measured for guidance and treatment verification. Contrast agent volume and C-arm CT utility were also measured. RESULTS: The marginal DAP increase in the test group was offset by a substantial (50%) decrease in CD from DSA. Use of C-arm CT allowed reduction of DAP and CD from DSA imaging (P = .007 and P = .017). Experienced operators were more efficient in substituting C-arm CT for DSA, resulting in a negligible increase (7.5%) in total DAP for guidance, compared with an increase of 34% for all operators (P = .03). For treatment verification, DAP from C-arm CT exceeded that from DSA, approaching that of conventional CT. The test group used less contrast medium (P = .001), and C-arm CT provided critical or supplemental information in 20% and 17% of patients, respectively. CONCLUSIONS: Routine use of C-arm CT can increase stochastic risk (DAP) but decrease deterministic risk (CD) from DSA. However, the increase in DAP is operator-dependent, thus, with experience, it can be reduced to under 10%. C-arm CT provides information not provided by DSA in 33% of patients, while decreasing the use of iodinated contrast medium. As with all radiation-emitting modalities, C-arm CT should be used judiciously.
Authors: W M H Busser; S J Braak; J J Fütterer; M J L van Strijen; Y L Hoogeveen; F de Lange; L J Schultze Kool Journal: Br J Radiol Date: 2013-08-02 Impact factor: 3.039
Authors: Bora Peynircioğlu; Mustafa Hızal; Barbaros Çil; Yu Deuerling-Zheng; Martin Von Roden; Tuncay Hazırolan; Deniz Akata; Mustafa Özmen; Ferhun Balkancı Journal: Diagn Interv Radiol Date: 2015 Jan-Feb Impact factor: 2.630