Literature DB >> 21872874

The current revolution in column technology: how it began, where is it going?

Fabrice Gritti1, Georges Guiochon.   

Abstract

This work revisits the exceptionally rapid evolution of the technology of chromatographic columns and the important progress in speed of analysis and resolution power that was achieved over the last ten years. Whereas columns packed with 10 and 5 μm fully porous particles dominated the field for nearly thirty years (1975-2000), it took barely six years to see the commercialization of monolithic silica rods (2000), their raise to fame and decay to oblivion, the development of finer fully porous particles with size down to 1.7 μm (2006), and of sub-3 μm superficially porous particles (2006). Analysis times and plate heights delivered by columns packed with these recent packing materials have then been improved by more than one order of magnitude in this short period of time. This progress has rendered practically obsolete the age-old design of LC instruments. For low molecular weight compounds, analysts can now achieve peak capacities of 40 peaks in about 15s with a hold-up time of the order of 1.5s , in gradient elution, by operating columns packed with sub-3 μm shell particles at elevated temperatures, provided that they use optimized high pressure liquid chromatographs. This is the ultimate limit allowed by modern instruments, which have an extra-column band broadening contribution of 7 μL² at 4.0 mL/min and data acquisition rate of 160 Hz. The best 2.1 mm × 50 mm narrow-bore columns packed with 1.7 μm silica core-shell particles provide peaks that have a variance of 2.1 μL² for k=1. Finally, this work discusses possible ways to accelerate separations and, in the same time perform these separations at the same level of efficiency as they have today. It seems possible to pack columns with smaller particles, probably down to 1 μm and operate them with current vHPLC equipments for separations of biochemicals. Analyses of low molecular weight compounds will require new micro-HPLC systems able to operate 1mm I.D. columns at pressures up to 5 kbar, which would eliminate the heat friction problems, and providing extra-column band broadening contributions smaller than 0.1 μL². Alternatively, a new generation of vHPLC systems with minimal extra-column contributions of less than 0.5 μL² could run 2.1mm I.D. columns if these latter were to be packed with high heat conductivity materials such as core-shell particles made with an alumina or gold core. Copyright Â
© 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21872874     DOI: 10.1016/j.chroma.2011.07.014

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  7 in total

1.  Advances in and prospects of microchip liquid chromatography.

Authors:  James P Grinias; Robert T Kennedy
Journal:  Trends Analyt Chem       Date:  2016 Jul-Aug       Impact factor: 12.296

2.  Now, More Than Ever, Proteomics Needs Better Chromatography.

Authors:  Evgenia Shishkova; Alexander S Hebert; Joshua J Coon
Journal:  Cell Syst       Date:  2016-10-26       Impact factor: 10.304

3.  Rapid methods for extracting and quantifying phenolic compounds in citrus rinds.

Authors:  Lembe Samukelo Magwaza; Umezuruike Linus Opara; Paul J R Cronje; Sandra Landahl; Jose Ordaz Ortiz; Leon A Terry
Journal:  Food Sci Nutr       Date:  2015-10-01       Impact factor: 2.863

4.  Development of Liquid-Chromatography Tandem-Mass-Spectrometry Method for Determining Environmental Contamination by Powdered Medicinal Drugs in Pharmacies.

Authors:  Shiori Hasegawa; Ryoichi Inaba; Hiroki Nakamura; Yamato Kato; Satoshi Nakao; Kouseki Hirade; Takaaki Suzuki; Mari Iwata; Takeshi Kato; Kazuhiro Iguchi; Masahide Yamada; Atsushi Hioki; Mitsuhiro Nakamura
Journal:  Inquiry       Date:  2021 Jan-Dec       Impact factor: 1.730

5.  Simultaneous analysis of the non-canonical amino acids norleucine and norvaline in biopharmaceutical-related fermentation processes by a new ultra-high performance liquid chromatography approach.

Authors:  Michael Biermann; Bettina Bardl; Sebastian Vollstädt; Julia Linnemann; Uwe Knüpfer; Guido Seidel; Uwe Horn
Journal:  Amino Acids       Date:  2013-01-11       Impact factor: 3.520

Review 6.  Are We Approaching a Speed Limit for the Chromatographic Separation of Enantiomers?

Authors:  Christopher J Welch
Journal:  ACS Cent Sci       Date:  2017-08-07       Impact factor: 14.553

7.  HPLC methods for purity evaluation of man-made single-stranded RNAs.

Authors:  Anastassia Kanavarioti
Journal:  Sci Rep       Date:  2019-01-31       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.