Literature DB >> 21872055

The CALUX bio-assay: analytical comparison between mouse hepatoma cell lines with a low (H1L6.1c3) and high (H1L7.5c1) number of dioxin response elements.

Kersten Van Langenhove1, Kim Croes, Michael S Denison, Marc Elskens, Willy Baeyens.   

Abstract

Dioxins, furans and polychlorinated biphenyls are contaminants of high concern and as such, sensitive tools are needed to detect these persistent organic compounds in a variety of matrices. Due to the large amount of samples that need to be investigated for example for food and feed control, the CALUX bioassay (H1L6.1 clone) was developed allowing rapid and cost-efficient analysis of biological and environmental samples. Recently, a new and more sensitive clone (H1L7.5) was constructed as the third generation CALUX bioassay. This new cell line was subject of an amplification of dioxin response elements (DREs), allowing lower concentrations of target compound to be analyzed. A comparison is made between the previous, well-defined H1L6.1c3 cell line and the new H1L7.5c1 cell line: it appears that the bioassay making use of the higher number of DREs is more stable and robust, shows better repeatability and reproducibility and is; on average, 3 times more sensitive.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21872055     DOI: 10.1016/j.talanta.2011.07.042

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Time-integrated monitoring of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in urban and industrial wastewaters using a ceramic toximeter and the CALUX bioassay.

Authors:  Amr Addeck; Kim Croes; Kersten Van Langenhove; Michael S Denison; Ahmed Elhamalawy; Marc Elskens; Willy Baeyens
Journal:  Chemosphere       Date:  2013-09-25       Impact factor: 7.086

2.  Time-integrated monitoring of dioxin-like polychlorinated biphenyls (dl-PCBs) in aquatic environments using the ceramic toximeter and the CALUX bioassay.

Authors:  Amr Addeck; Kim Croes; Kersten Van Langenhove; Michael S Denison; Ahmed S Afify; Yue Gao; Marc Elskens; Willy Baeyens
Journal:  Talanta       Date:  2013-12-16       Impact factor: 6.057

3.  Gut Symbionts Lactobacillus reuteri R2lc and 2010 Encode a Polyketide Synthase Cluster That Activates the Mammalian Aryl Hydrocarbon Receptor.

Authors:  Mustafa Özçam; Restituto Tocmo; Jee-Hwan Oh; Amin Afrazi; Joshua D Mezrich; Stefan Roos; Jan Claesen; Jan-Peter van Pijkeren
Journal:  Appl Environ Microbiol       Date:  2019-05-02       Impact factor: 4.792

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.