Literature DB >> 21871630

Exploration of overloaded cation exchange chromatography for monoclonal antibody purification.

Hui F Liu1, Beth McCooey, Tiago Duarte, Deanna E Myers, Terry Hudson, Ashraf Amanullah, Robert van Reis, Brian D Kelley.   

Abstract

Cation exchange chromatography using conventional resins, having either diffusive or perfusive flow paths, operated in bind-elute mode has been commonly employed in monoclonal antibody (MAb) purification processes. In this study, the performance of diffusive and perfusive cation exchange resins (SP-Sepharose FF (SPSFF) and Poros 50HS) and a convective cation exchange membrane (Mustang S) and monolith (SO(3) Monolith) were compared. All matrices were utilized in an isocratic state under typical binding conditions with an antibody load of up to 1000 g/L of chromatographic matrix. The dynamic binding capacity of the cation exchange resins is typically below 100 g/L resin, so they were loaded beyond the point of anticipated MAb break through. All of the matrices performed similarly in that they effectively retained host cell protein and DNA during the loading and wash steps, while antibody flowed through each matrix after its dynamic binding capacity was reached. The matrices differed, though, in that conventional diffusive and perfusive chromatographic resins (SPSFF and Poros 50HS) demonstrated a higher binding capacity for high molecular weight species (HMW) than convective flow matrices (membrane and monolith); Poros 50HS displayed the highest HMW binding capacity. Further exploration of the conventional chromatographic resins in an isocratic overloaded mode demonstrated that the impurity binding capacity was well maintained on Poros 50HS, but not on SPSFF, when the operating flow rate was as high as 36 column volumes per hour. Host cell protein and HMW removal by Poros 50HS was affected by altering the loading conductivity. A higher percentage of host cell protein removal was achieved at a low conductivity of 3 mS/cm. HMW binding capacity was optimized at 5 mS/cm. Our data from runs on Poros 50HS resin also showed that leached protein A and cell culture additive such as gentamicin were able to be removed under the isocratic overloaded condition. Lastly, a MAb purification process employing protein A affinity chromatography, isocratic overloaded cation exchange chromatography using Poros 50HS and anion exchange chromatography using QSFF in flow through mode was compared with the MAb's commercial manufacturing process, which consisted of protein A affinity chromatography, cation exchange chromatography using SPSFF in bind-elute mode and anion exchange chromatography using QSFF in flow through mode. Comparable step yield and impurity clearance were obtained by the two processes.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21871630     DOI: 10.1016/j.chroma.2011.08.008

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Development of adsorptive hybrid filters to enable two-step purification of biologics.

Authors:  Nripen Singh; Abhiram Arunkumar; Michael Peck; Alexei M Voloshin; Angela M Moreno; Zhijun Tan; Jonathan Hester; Michael C Borys; Zheng Jian Li
Journal:  MAbs       Date:  2016-12-08       Impact factor: 5.857

2.  Ionic strength-dependent changes in tentacular ion exchangers with variable ligand density. I. Structural properties.

Authors:  Rahul Bhambure; Christopher M Gillespie; Michael Phillips; Heiner Graalfs; Abraham M Lenhoff
Journal:  J Chromatogr A       Date:  2016-08-09       Impact factor: 4.759

Review 3.  A common framework for integrated and continuous biomanufacturing.

Authors:  Jonathan Coffman; Mark Brower; Lisa Connell-Crowley; Sevda Deldari; Suzanne S Farid; Brian Horowski; Ujwal Patil; David Pollard; Maen Qadan; Steven Rose; Eugene Schaefer; Joseph Shultz
Journal:  Biotechnol Bioeng       Date:  2021-03-01       Impact factor: 4.530

4.  In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies.

Authors:  Maxime Boulet-Audet; Sergei G Kazarian; Bernadette Byrne
Journal:  Sci Rep       Date:  2016-07-29       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.