Literature DB >> 21865781

Mass transfer mechanisms in high-performance membrane dialyzers.

Akihiro C Yamashita1.   

Abstract

Four dialyzers with super-high-flux membrane or high-performance membrane (HPM) with varying packing density of the hollow fiber (PDF) from 29.6 to 53.1% were investigated in aqueous in vitro experiments for the purpose of identifying the mass transfer mechanism for three test solutes. Clearances for relatively small test solutes (creatinine and vitamin B(12)) slowly increased with PDF and reached plateau since mass transfer mechanism of these solutes was diffusion limited. However, since unlike classic high-flux dialyzers a considerable amount of internal filtration ( > 20 ml/min) should occur in super-high-flux dialyzers even under relatively reduced blood and dialysis fluid flow rates, Q(B) = 200 ml/min and Q(D) = 500 ml/min, it should contribute to enhance the rate of mass transfer especially for those solutes that cannot be easily removed by diffusion, such as β(2)-microglobulin or even larger toxic substances. For dialyzers with the HPM a module design becomes even more important for developing novel commercial products.
Copyright © 2011 S. Karger AG, Basel.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21865781     DOI: 10.1159/000328946

Source DB:  PubMed          Journal:  Contrib Nephrol        ISSN: 0302-5144            Impact factor:   1.580


  5 in total

Review 1.  Flummoxed by flux: the indeterminate principles of haemodialysis.

Authors:  Sudhir K Bowry; Fatih Kircelli; Madhukar Misra
Journal:  Clin Kidney J       Date:  2021-12-27

2.  Changes of Early Sepsis Biomarker Presepsin Level during Hemodialysis: Influence of β2-Microglobulin Clearance of Dialysis Membrane: A Preliminary Study.

Authors:  Jun Shiota
Journal:  Kidney Dis (Basel)       Date:  2018-10-09

3.  Effect of dialyzer membrane materials on survival in chronic hemodialysis patients: Results from the annual survey of the Japanese Nationwide Dialysis Registry.

Authors:  Masanori Abe; Takayuki Hamano; Atsushi Wada; Shigeru Nakai; Ikuto Masakane
Journal:  PLoS One       Date:  2017-09-14       Impact factor: 3.240

4.  Super high-flux membrane dialyzers improve mortality in patients on hemodialysis: a 3-year nationwide cohort study.

Authors:  Masanori Abe; Ikuto Masakane; Atsushi Wada; Shigeru Nakai; Kosaku Nitta; Hidetomo Nakamoto
Journal:  Clin Kidney J       Date:  2021-09-28

5.  Dialyzer surface area is a significant predictor of mortality in patients on hemodialysis: a 3-year nationwide cohort study.

Authors:  Masanori Abe; Ikuto Masakane; Atsushi Wada; Shigeru Nakai; Kosaku Nitta; Hidetomo Nakamoto
Journal:  Sci Rep       Date:  2021-10-18       Impact factor: 4.379