Literature DB >> 21864968

The effect of splinting implant-supported restorations on stress distribution of different crown-implant ratios and crown height spaces.

Joseph Nissan1, Ora Gross, Oded Ghelfan, Ilan Priel, Martin Gross, Gavriel Chaushu.   

Abstract

PURPOSE: To assess whether splinting can counterbalance the detrimental effects of varying the crown-to-implant (C/I) ratio and crown height space (CHS) by decreasing nonaxial overload stresses.
MATERIALS AND METHODS: Three implants were inserted into a photoelastic block model. Two strain gauges were cemented onto the neck of each implant on the buccal and lingual aspects and provided a simultaneous direct reading of strain. Four groups of splinted cement-retained restorations with C/I ratios of 1:1, 1:1.5, 1:1.75, and 1:2 were used. CHSs were 10, 15, 17.5, and 20 mm, respectively. Fifteen static loadings were carried out simultaneously with 20-kg weights via a custom-built loading apparatus at 30° to the vertical axis.
RESULTS: Occlusal force application at 30° showed a statistically significant increase in both buccal (1,911.65 ± 110 vs 3,252.06 ± 150) and palatal (35.58 ± 7 vs 286.85 ± 15) microstrain values as the C/I ratio increased from 1:1 to 1:1.5 (P < .001). Force application at 30° in cases with C/I ratios of 1:1.75 and 1:2 resulted in fracture of the abutment screw followed by dislodgement of the crowns. Failures were noted at a CHS of 15 mm or greater.
CONCLUSIONS: In this biomechanical mode, splinting does not prevent prosthetic failure when the CHS is 15 mm or greater. Vertical bone augmentation is highly recommended in cases with a CHS of 15 mm or greater.
Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21864968     DOI: 10.1016/j.joms.2011.06.210

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  5 in total

1.  Influence of Implant Tilting and Length on the Biomechanics of Single-Tooth Restoration: A Finite Element Analysis in Atrophic Mandible.

Authors:  Eduardo Anitua; Naiara Larrazabal Saez de Ibarra; Iñigo Morales Martín; Luis Saracho Rotaeche
Journal:  Dent J (Basel)       Date:  2022-05-06

2.  The Mechanical Behavior of a Screwless Morse Taper Implant-Abutment Connection: An In Vitro Study.

Authors:  Aimen Bagegni; Vincent Weihrauch; Kirstin Vach; Ralf Kohal
Journal:  Materials (Basel)       Date:  2022-05-08       Impact factor: 3.748

3.  The prognosis of splinted restoration of the most-distal implants in the posterior region.

Authors:  Jong-Bin Lee; Man-Yong Kim; Chang-Sung Kim; Young-Taek Kim
Journal:  J Adv Prosthodont       Date:  2016-12-15       Impact factor: 1.904

Review 4.  Sinus bone graft and simultaneous vertical ridge augmentation: case series study.

Authors:  Dong-Woo Kang; Pil-Young Yun; Yong-Hoon Choi; Young-Kyun Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2019-09-16

5.  Increased crown-to-implant ratio may not be a risk factor for dental implant failure under appropriate plaque control.

Authors:  Shinsuke Okada; Katsunori Koretake; Yasunari Miyamoto; Hiroshi Oue; Yasumasa Akagawa
Journal:  PLoS One       Date:  2013-05-30       Impact factor: 3.240

  5 in total