Literature DB >> 21864744

Continuous blood glucose monitoring in diabetes treatment.

Andriani Vazeou1.   

Abstract

Continuous glucose monitoring system (CGMS) is a developing technology in the field of diabetes treatment since it enables patients to effectively control and adjust their insulin therapy. Clinical trials have shown its efficacy in lowering HbAlc significantly especially in adults with type 1 diabetes and those with HbAlc >8%. Improvement is sustained for at least one year. Conflicting data exist for children. Most recent studies agree that the nearly daily use of CGMS is accompanied by significant lowering of HbA1c independent of age. However, the randomized clinical trials have shown that the use of CGMS does not reduce significantly the number of severe hypoglycemic episodes as it is expected, but recent data indicate that it reduces the time spent in hypoglycemia. Accuracy remains a key issue for CGMS, particularly in children and adolescents who may have increased variability of blood glucose. CGMS cost is another barrier to the everyday use since reimbursement of CGM is limited to a few countries only. This review will focus on the present status of the use of CGMS in type 1 diabetes (T1D) patients.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21864744     DOI: 10.1016/S0168-8227(11)70028-6

Source DB:  PubMed          Journal:  Diabetes Res Clin Pract        ISSN: 0168-8227            Impact factor:   5.602


  7 in total

Review 1.  Treating type 1 diabetes: from strategies for insulin delivery to dual hormonal control.

Authors:  A L McCall; L S Farhy
Journal:  Minerva Endocrinol       Date:  2013-06       Impact factor: 2.184

2.  Technological Ecological Momentary Assessment Tools to Study Type 1 Diabetes in Youth: Viewpoint of Methodologies.

Authors:  Mary Katherine Ray; Alana McMichael; Maria Rivera-Santana; Jacob Noel; Tamara Hershey
Journal:  JMIR Diabetes       Date:  2021-06-03

3.  Glycated albumin (GA) and the GA/HbA1c ratio are higher in diabetic patients positive for insulin antibodies with high binding capacity and low affinity.

Authors:  Takehito Takeuchi; Yushi Hirota; Yasushi Nakagawa; Atsuko Matsuoka; Tetsushi Hamaguchi; Yuko Okada; Kazuhiko Sakaguchi; Wataru Ogawa; Masafumi Koga
Journal:  Diabetol Int       Date:  2021-08-18

4.  Hypoglycemia identified by a continuous glucose monitoring system in a second-trimester pregnant woman with insulinoma: a case report.

Authors:  Marjeta Tomazic; Andrej Janez; Maja Ravnik Oblak
Journal:  J Med Case Rep       Date:  2017-04-21

Review 5.  Complications of Diabetes and Metrics of Glycemic Management Derived From Continuous Glucose Monitoring.

Authors:  Michael Yapanis; Steven James; Maria E Craig; David O'Neal; Elif I Ekinci
Journal:  J Clin Endocrinol Metab       Date:  2022-05-17       Impact factor: 6.134

Review 6.  Continuous Glucose Monitoring Systems: A Review.

Authors:  Sandeep Kumar Vashist
Journal:  Diagnostics (Basel)       Date:  2013-10-29

Review 7.  Revascularization of transplanted pancreatic islets and role of the transplantation site.

Authors:  Andrew R Pepper; Boris Gala-Lopez; Oliver Ziff; A M James Shapiro
Journal:  Clin Dev Immunol       Date:  2013-09-09
  7 in total