Literature DB >> 21864498

Protein chip for the parallel quantification of high and low abundant biomarkers for sepsis.

Ursula Sauer1, Patrick Domnanich, Claudia Preininger.   

Abstract

We present herein a protein chip for diagnosis of sepsis that combines both a sandwich and a binding inhibition format in order to quantify high (CRP) and low abundant proteins (cytokines, PCT, neopterin) in parallel. Using the combined assay format the lowest detectable concentrations for CRP, IL-6, IL-8, IL-10, TNFα, PCT, and neopterin are 3 mg/L, 15 ng/L, 26 ng/L, 65 ng/L, 40 ng/L, 78 ng/L, and 0.46 μg/L. Four different combined assay formats are tested, using separate or joint incubation steps of analytes and detection antibodies. Yet, low limit of detection (LOD) and short processing time are contradictory: while the combined assay performed in a multistep protocol is extremely sensitive (e.g., the LOD for IL-6 is 15 ng/L), but more time-consuming (4 h), the all-in-one protocol takes only 2.5 h, but suffers from lower sensitivity compared with the multistep protocol (e.g., the LOD for IL-6 is up to 40 times enhanced). Reproducibility is good in both cases (CV 5-20%).
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21864498     DOI: 10.1016/j.ab.2011.07.038

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  5 in total

Review 1.  Point of care technologies for sepsis diagnosis and treatment.

Authors:  Taylor Oeschger; Duncan McCloskey; Varun Kopparthy; Ankur Singh; David Erickson
Journal:  Lab Chip       Date:  2019-02-26       Impact factor: 6.799

2.  The IL-6 Paradox: Context Dependent Interplay of SOCS3 and AMPK.

Authors:  Jessica L Sarvas; Neelam Khaper; Simon J Lees
Journal:  J Diabetes Metab       Date:  2013-05-24

3.  Miniaturized protein microarray with internal calibration as point-of-care device for diagnosis of neonatal sepsis.

Authors:  Patricia Buchegger; Ursula Sauer; Hedvig Toth-Székély; Claudia Preininger
Journal:  Sensors (Basel)       Date:  2012-02-03       Impact factor: 3.576

Review 4.  Analytical Protein Microarrays: Advancements Towards Clinical Applications.

Authors:  Ursula Sauer
Journal:  Sensors (Basel)       Date:  2017-01-29       Impact factor: 3.576

5.  Magnetic Bead-Based Electrochemical Immunoassays On-Drop and On-Chip for Procalcitonin Determination: Disposable Tools for Clinical Sepsis Diagnosis.

Authors:  Águeda Molinero-Fernández; María Moreno-Guzmán; Miguel Ángel López; Alberto Escarpa
Journal:  Biosensors (Basel)       Date:  2020-06-17
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.