Literature DB >> 21863217

Development of a liposome-based immunochromatographic strip assay for the detection of Salmonella.

Shruti Shukla1, Hyerim Leem, Myunghee Kim.   

Abstract

Salmonella species are ubiquitous human pathogens which pose a dangerous threat to the elderly and children worldwide. In this study, to develop a more efficient assay procedure for the rapid detection of Salmonella Typhimurium, an immunochromatographic strip assay was developed using immunoliposome (anti-Salmonella IgG-tagged) encapsulated with sulforhodamine B (SRB). The detection sensitivity of the developed immunochromatographic assay was compared with a commercial immunochromatographic test strip using colloidal gold nanoparticles. The liposomes were prepared through a reverse-phase evaporation method by using a lipid and phospholipid mixture and SRB, a fluorescence dye, which was encapsulated in the phospholipid bilayer. Furthermore, the outer surface of the SRB-encapsulated liposome was conjugated with antibody (affinity-purified polyclonal goat anti-Salmonella IgG) to form an immunoliposome (size, 223 nm), used as the analytical reagent in the developed immunoassay. For this strip assay, a plastic-backed nitrocellulose strip was immobilized with two antibody zones. The lower zone of the strip referred to Salmonella antigen capture zone (test line), while the other zone served as a positive control (control line). The lower zone was coated with affinity-purified polyclonal goat anti-Salmonella IgG, while the upper zone was coated with rabbit anti-goat IgG. During capillary migration of the wicking solution (diluted liposome and Salmonella culture, each 50 μl), Salmonella was captured with surface-bound immunoliposomes at the antigen capture zone, while the unbound liposomes migrated upward and bound to another zone. The color density of the antigen capture zone was directly proportional to the amount of S. Typhimurium in the test sample. As a result, the detection limit of the immunochromatographic strip assay developed in this study against S. Typhimurium was found to be 10(2) CFU/ml, which was significantly higher than the detection limit (10(7) CFU/ml) of the commercial immunochromatographic test strip assay.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21863217     DOI: 10.1007/s00216-011-5327-2

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  13 in total

Review 1.  Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments.

Authors:  Yan Huang; Tailin Xu; Wenqian Wang; Yongqiang Wen; Kun Li; Lisheng Qian; Xueji Zhang; Guodong Liu
Journal:  Mikrochim Acta       Date:  2019-12-18       Impact factor: 5.833

2.  Paper-based lateral flow assay using rhodamine B-loaded polymersomes for the colorimetric determination of synthetic cannabinoids in saliva.

Authors:  Hichem Moulahoum; Faezeh Ghorbanizamani; Suna Timur
Journal:  Mikrochim Acta       Date:  2021-11-03       Impact factor: 5.833

3.  Development of fluorescence-based liposome immunoassay for detection of Cronobacter muytjensii in pure culture.

Authors:  Xinjie Song; Shruti Shukla; Sejong Oh; Younghoan Kim; Myunghee Kim
Journal:  Curr Microbiol       Date:  2014-10-10       Impact factor: 2.188

Review 4.  Rapid methods for the detection of foodborne bacterial pathogens: principles, applications, advantages and limitations.

Authors:  Jodi Woan-Fei Law; Nurul-Syakima Ab Mutalib; Kok-Gan Chan; Learn-Han Lee
Journal:  Front Microbiol       Date:  2015-01-12       Impact factor: 5.640

5.  Detection of Cronobacter sakazakii in powdered infant formula using an immunoliposome-based immunomagnetic concentration and separation assay.

Authors:  Shruti Shukla; Gibaek Lee; Xinjie Song; Jung Hyun Park; Hyunjeong Cho; Eun Ju Lee; Myunghee Kim
Journal:  Sci Rep       Date:  2016-10-10       Impact factor: 4.379

Review 6.  Current Demands for Food-Approved Liposome Nanoparticles in Food and Safety Sector.

Authors:  Shruti Shukla; Yuvaraj Haldorai; Seung Kyu Hwang; Vivek K Bajpai; Yun Suk Huh; Young-Kyu Han
Journal:  Front Microbiol       Date:  2017-12-05       Impact factor: 5.640

7.  Development of gold nanoparticle-aptamer-based LSPR sensing chips for the rapid detection of Salmonella typhimurium in pork meat.

Authors:  Seo Yeong Oh; Nam Su Heo; Shruti Shukla; Hye-Jin Cho; A T Ezhil Vilian; Jinwoon Kim; Sang Yup Lee; Young-Kyu Han; Seung Min Yoo; Yun Suk Huh
Journal:  Sci Rep       Date:  2017-08-31       Impact factor: 4.379

Review 8.  Current Technical Approaches for the Early Detection of Foodborne Pathogens: Challenges and Opportunities.

Authors:  Il-Hoon Cho; Seockmo Ku
Journal:  Int J Mol Sci       Date:  2017-09-30       Impact factor: 5.923

9.  Direct Detection of Escherichia coli, Staphylococcus aureus, and Salmonella spp. in Animal-derived Foods Using a Magnetic Bead-based Immunoassay.

Authors:  Jong-Hui Kim; Jae Gyu Yoo; Jun-Sang Ham; Mi-Hwa Oh
Journal:  Korean J Food Sci Anim Resour       Date:  2018-09-30       Impact factor: 2.622

10.  A novel diagnostic approach to detecting porcine epidemic diarrhea virus: The lateral immunochromatography assay.

Authors:  Yong Kwan Kim; Seong-In Lim; In-Soo Cho; Kwang-Myun Cheong; Eun-Jeong Lee; Sang-Oh Lee; Joon-Bae Kim; Jung-Hwa Kim; Dong-Soo Jeong; Byung-Hyun An; Dong-Jun An
Journal:  J Virol Methods       Date:  2015-09-02       Impact factor: 2.014

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.