Literature DB >> 21861974

Evaluation of posterior lens capsule by 20-MHz ultrasound probe in traumatic cataract.

Ali Tabatabaei1, Mohammad Yaser Kiarudi, Fariba Ghassemi, Sasan Moghimi, Mohammadreza Mansouri, Ahmad Mirshahi, Ahmad Kheirkhah.   

Abstract

PURPOSE: To investigate the accuracy of echography with a 20-MHz probe for evaluation of posterior lens capsule in traumatic cataract before surgery.
DESIGN: Prospective interventional case series.
METHODS: This study consisted of 43 eyes with traumatic cataract that were scheduled to undergo surgery. In all cases, cataract was dense enough to prevent visualization of the posterior lens capsule. Echography was performed using a 20-MHz probe to detect rupture of the posterior lens capsule. All patients subsequently underwent cataract extraction and intraoperative findings of the posterior lens capsule were compared with the preoperative echographic findings.
RESULTS: This study included 43 eyes of 43 patients (38 men and 5 women) with a mean age of 35.6 ± 15.3 years (range, 4-68 years). The trauma was either blunt (4 eyes) or sharp (39 eyes); there was closed globe injury in 2 eyes and open globe injury in 41 eyes. By 20-MHz echography, posterior border of the crsytalline lens was clearly visualized in all 43 eyes. By 20-MHz echographic imaging, rupture of the posterior lens capsule was identified in 17 eyes (39.5%). During cataract surgery, it was noted that 14 eyes (32.6%) had rupture of the posterior lens capsule. Sensitivity, specificity, positive predictive value, and negative predictive value were 93%, 86%, 76%, and 96%, respectively, for 20-MHz echography to detect rupture of the posterior lens capsule. Also, the positive likelihood ratio, negative likelihood ratio, and odds ratio were 6.7, 0.08, and 81, respectively.
CONCLUSION: Echography with 20-MHz probe is an accurate imaging modality for detection of posterior lens capsule rupture in traumatic cataract preoperatively. This technique helps ophthalmologists have an appropriate surgical plan before operating.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21861974     DOI: 10.1016/j.ajo.2011.05.038

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  12 in total

1.  Evaluation of immersion 20 MHz B-scan ultrasonography in observing lens in the alkali burn eyes.

Authors:  Qing-Hua Yang; Bing Chen; Li-Qiang Wang; Guang-Hua Peng; Zhao-Hui Li; Yi-Fei Huang
Journal:  Int J Ophthalmol       Date:  2014-08-18       Impact factor: 1.779

2.  Establishing a novel lens opacities classification system based on ultrasound biomicroscopy (UBM) for pediatric cataracts: reliability and availability.

Authors:  Dao-Man Xiang; Nan Jiang; Li-Hong Chen; Wen-Si Chen; Ying Yu; Jian-Xun Wang; Ping He; Wan-Hua Xie
Journal:  Quant Imaging Med Surg       Date:  2021-11

3.  Refractive outcomes of scleral-sutured posterior chamber intraocular lenses in post-traumatic eyes.

Authors:  Wenlong Wei; Haishuang Lin; Xuanli Zheng; Siyi Wang; Shengsheng Bai; Zhenquan Zhao
Journal:  Int Ophthalmol       Date:  2022-08-23       Impact factor: 2.029

4.  Comparison of 25 MHz and 50 MHz ultrasound biomicroscopy for imaging of the lens and its related diseases.

Authors:  Ming-Yu Shi; Xiao Han; Jin-Song Zhang; Qi-Chang Yan
Journal:  Int J Ophthalmol       Date:  2018-07-18       Impact factor: 1.779

5.  Role of ultrasound biomicroscopy in the planning for secondary implantation of intra ocular lens in aphakia.

Authors:  Mohamed Elfiky; Hisham Saad; Rabab Elseht; Adel Selima
Journal:  Int Ophthalmol       Date:  2015-10-22       Impact factor: 2.031

6.  Intraocular lens implantation in the absence of capsular support: iris fixation.

Authors:  Michael Tsatsos; Georgios Vartsakis; Ioannis Athanasiadis; Evangelia Papavasileiou; Nilufer Yesilirmak; Nikolaos Ziakas
Journal:  Eye (Lond)       Date:  2022-03-24       Impact factor: 4.456

7.  Isolated posterior capsular rupture following blunt head trauma.

Authors:  Ahmad M Mansour; Mahmoud O Jaroudi; Rola N Hamam; Fadi C Maalouf
Journal:  Clin Ophthalmol       Date:  2014-11-28

8.  Femtosecond laser-assisted cataract surgery in management of posterior capsule tear following blunt trauma: Case report and review of literature.

Authors:  Alisa J Prager; Surendra Basti
Journal:  Am J Ophthalmol Case Rep       Date:  2020-05-16

9.  Role of 25 MHz Ultrasound Biomicroscopy in the Detection of Subluxated Lenses.

Authors:  Mingyu Shi; Liwei Ma; Jinsong Zhang; Qichang Yan
Journal:  J Ophthalmol       Date:  2018-10-17       Impact factor: 1.909

10.  Application of 14-MHz Ultrasonography with Tissue Harmonic Imaging to Determine Posterior Capsule Integrity in Traumatic Cataract.

Authors:  Bin Wu; Qingyu Li; Yangchen Liu; Di Wu; Jianmin Gao; Yan Li; Xiaoyong Yuan
Journal:  J Ophthalmol       Date:  2019-11-12       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.