Literature DB >> 21860924

Comparison between cone-beam and multislice computed tomography for identification of simulated bone lesions.

Bruno Felipe Gaia1, Marcelo Augusto Oliveira de Sales, Andréia Perrella, Marlene Fenyo-Pereira, Marcelo Gusmão Paraíso Cavalcanti.   

Abstract

There are many studies that compare the accuracy of multislice (MSCT) and cone beam (CBCT) computed tomography for evaluations in the maxillofacial region. However, further studies comparing both acquisition techniques for the evaluation of simulated mandibular bone lesions are needed. The aim of this study was to compare the accuracy of MSCT and CBCT in the diagnosis of simulated mandibular bone lesions by means of cross sectional images and axial/MPR slices. Lesions with different dimensions, shape and locularity were produced in 15 dry mandibles. The images were obtained following the cross sectional and axial/MPR (Multiplanar Reconstruction) imaging protocols and were interpreted independently. CBCT and MSCT showed similar results in depicting the percentage of cortical bone involvement, with great sensitivity and specificity (p < 0.005). There were no significant intra- or inter-examiner differences between axial/MPR images and cross sectional images with regard to sensitivity and specificity. CBCT showed results similar to those of MSCT for the identification of the number of simulated bone lesions. Cross sectional slices and axial/MPR images presented high accuracy, proving useful for bone lesion diagnosis.

Entities:  

Mesh:

Year:  2011        PMID: 21860924     DOI: 10.1590/s1806-83242011000400014

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  6 in total

Review 1.  Cone-beam CT in paediatric dentistry: DIMITRA project position statement.

Authors:  Anne Caroline Oenning; Reinhilde Jacobs; Ruben Pauwels; Andreas Stratis; Mihaela Hedesiu; Benjamin Salmon
Journal:  Pediatr Radiol       Date:  2017-11-15

2.  Evaluation of mandibular odontogenic keratocyst and ameloblastoma by panoramic radiograph and computed tomography.

Authors:  Daniel Berretta Moreira Alves; Fabrício Mesquita Tuji; Fábio Abreu Alves; André Caroli Rocha; Alan Roger Dos Santos-Silva; Pablo Agustin Vargas; Márcio Ajudarte Lopes
Journal:  Dentomaxillofac Radiol       Date:  2018-06-05       Impact factor: 2.419

3.  Cone beam CT image artefacts related to head motion simulated by a robot skull: visual characteristics and impact on image quality.

Authors:  R Spin-Neto; J Mudrak; L H Matzen; J Christensen; E Gotfredsen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2012-07-27       Impact factor: 2.419

4.  Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography.

Authors:  Abbas Shokri; Amir Eskandarloo; Maruf Noruzi-Gangachin; Samira Khajeh
Journal:  Restor Dent Endod       Date:  2014-11-13

5.  A dose-neutral image quality comparison of different CBCT and CT systems using paranasal sinus imaging protocols and phantoms.

Authors:  Ari-Petteri Ronkainen; Ali Al-Gburi; Timo Liimatainen; Hanna Matikka
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-01-27       Impact factor: 3.236

6.  Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects.

Authors:  Roghieh Bardal; Hassan Jahanihashemi; Maryam Mostafavi; Esmaeil Kalhor; Maryam Tofangchiha; Mahdieh Dehghani
Journal:  J Dent (Tehran)       Date:  2015-11
  6 in total