| Literature DB >> 21860776 |
Gulbanu Erkan1, Aycan Fahri Erkan, Mustafa Cemri, Selma Karaahmetoglu, Mustafa Cesur, Atiye Cengel.
Abstract
Background. Subclinical hypothyroidism (SH) predominantly affects women. The necessity of treatment in SH is controversial. Objective. We aimed to investigate the response of diastolic dysfunction to thyroid hormone replacement therapy (THRT) in women. Methods and Results. Twenty-two female subjects with SH and 20 euthyroid female controls were enrolled. Baseline and follow-up biochemical, hormonal, and echocardiographic evaluations were performed. Repeat echocardiograms were performed three months after the achievement of a euthyroid status with THRT. Mean baseline myocardial performance index (MPI) was 0.27 ± 0.08 in the SH group, and 0.22 ± 0.06 in the control group (P = 0.03). MPI did not change significantly after THRT. Pulsed-wave Doppler findings were not different among the groups. However, tissue Doppler-derived mitral annular E' velocities were significantly lower in the SH group. A moderate but significant improvement was observed in E' velocities after THRT (13.2 ± 3.87 versus 14.53 ± 2.75, P = 0.04). We also observed left ventricular concentric remodeling in SH patients which was reversible with THRT. Conclusions. Tissue Doppler echocardiography may be a useful tool for monitoring the response of diastolic dysfunction to thyroid hormone replacement therapy in patients with SH. Our findings suggest that THRT may reverse diastolic dysfunction in women with SH.Entities:
Year: 2011 PMID: 21860776 PMCID: PMC3153938 DOI: 10.4061/2011/654304
Source DB: PubMed Journal: J Thyroid Res
Thyroid function tests before and after thyroid hormone replacement therapy (THRT).
| Before THRT | After THRT | ||
|---|---|---|---|
| fT3 (pg/mL) | 2.62 ± 0.39 | 2.67 ± 0.44 | 0.07 |
| fT4 (ng/dL) | 0.89 ± 0.13 | 1.02 ± 0.12 | |
| TSH ( | 7.17 ± 1.74 | 2.28 ± 0.63 |
fT3: free triiodothyronine; fT4: free thyroxine; TSH: thyroid stimulating hormone.
Two-dimensional (2D) echocardiographic findings.
| SH | Control | ||
|---|---|---|---|
| LVEF (%) | 71.72 (4,61) | 74.2 (4,68) | 0.09 |
| IVS (cm) | 0.97 (0,12) | 0.88 (0,1) | |
| Posterior wall (cm) | 1.0 (0,13) | 0.92 (0,13) | |
| LVEDD (cm) | 4,61 (0.34) | 4.73 (0.35) | 0.29 |
| LVESD (cm) | 2.92 (0.26) | 2.90 (0.32) | 0.84 |
LVEF: Left ventricular ejection fraction; IVS: interventricular septum; LVEDD: Left ventricular end-diastolic diameter; LVESD: Left ventricular end-systolic diameter.
All results are expressed as mean values and numbers in brackets denote Standard Deviation.
Pulsed wave Doppler-derived parameters.
| SH | Control | ||
|---|---|---|---|
| E vel (cm/sn) | 84 (0.14) | 86 (0.13) | 0.67 |
| A vel (cm/sn) | 64 (0.16) | 60 (0.11) | 0.37 |
| E/A | 1.39 (0.33) | 1.44 (0.15) | 0.58 |
| DT (msn) | 178.86 (41.98) | 169.26 (23.68) | 0.37 |
| ET (msn) | 297.68 (21.10) | 298.20 (19.83) | 0.93 |
| MPI | 0.27 (0.08) | 0.22 (0.06) |
E vel: E wave velocity; A vel: A wave velocity; DT: Deceleration time (of mitral E wave); ET: Ejection time; MPI: Myocardial performance index.
All results are expressed as mean values and numbers in brackets denote Standard Deviation.
Tissue Doppler-derived parameters.
| SH | Control | ||
|---|---|---|---|
| Septal S | 7.68 (0.97) | 8.14 (0.99) | 0.14 |
| Lateral S | 9.52 (1.73) | 9.42 (1.50) | 0.83 |
| Anterior S | 8.83 (1.94) | 8.32 (0.90) | 0.29 |
| Inferior S | 8.21 (1.13) | 8.49 (0.96) | 0.40 |
| Septal E′ | 11.45 (3.24) | 13.24 (2.44) | |
| Lateral E′ | 15.70 (3.97) | 16.89 (2.74) | 0.27 |
| Anterior E′ | 13.20 (3.87) | 15.65 (2.43) | |
| Inferior E′ | 13.47 (3.77) | 14.94 (2.10) | 0.13 |
| Septal A′ | 9.15 (2.28) | 8.65 (1.39) | 0.40 |
| Lateral A′ | 10.14 (2.74) | 9.85 (1.61) | 0.67 |
| Anterior A′ | 9.70 (2.94) | 9.22 (1.24) | 0.49 |
| Inferior A′ | 9.92 (2.08) | 9.25 (1.45) | 0.24 |
| Mean E′ | 13.70 (3.39) | 15.12 (2.26) | 0.12 |
| Mean A′ | 9.63 (2.27) | 9.24 (0.97) | 0.47 |
| E′/A′ | 1.52 (0.58) | 1.63 (0.25) | 0.43 |
| E/E′ | 6.13 (1.12) | 5.09 (1.08) | 0.15 |
All results are expressed as mean values and numbers in brackets denote Standard Deviation.
Response of 2D and M-Mode echocardiographic parameters to thyroid hormone replacement therapy.
| Before treatment | After treatment | ||
|---|---|---|---|
| LVEF (%) | 71,72 (4,61) | 72,77 (4,67) | 0,50 |
| DIASTOLIC SEPTUM THICKNESS (cm) | 0,97 (0,12) | 0,93 (0,10) | 0,21 |
| DIASTOLIC POSTERIOR WALL THICKNESS (cm) | 1,0 (0,13) | 0,92 (0,11) | |
| LV EDD (cm) | 4,61 (0,34) | 4,64 (0,40) | 0,71 |
| LV ESD (cm) | 2,92 (0,26) | 2,95 (0,34) | 0,70 |
| LVMI (gr/m2) | 77,34 (2,14) | 77,21 (2,27) | 0,43 |
LVEF: Left ventricular ejection fraction; LVEDD: Left ventricular end-diastolic diameter; LVESD: Left ventricular end-systolic diameter; LVMI: Left venticular mass index.
All results are expressed as mean values and numbers in brackets denote Standard Deviation.
The response of tissue Doppler-derived parameters to thyroid hormone replacement therapy.
| Before treatment | After treatment | ||
|---|---|---|---|
| SEPTAL S VELOCITY (cm/sn) | 7,68 (0,97) | 7,63 (0,99) | 0,85 |
| LAT S VELOCITY (cm/sn) | 9,52 (1,73) | 8,86 (1,19) | 0,11 |
| ANT S VELOCITY (cm/sn) | 8,83 (1,94) | 8,17 (1,10) | 0,16 |
| INF S VELOCITY (cm/sn) | 8,21 (1,13) | 8,22 (0,83) | 0,97 |
| SEP E′ VELOCITY (cm/sn) | 11,45 (3,24) | 11,94 (2,89) | 0,45 |
| LAT E′ VELOCITY (cm/sn) | 15,70 (3,97) | 16,43 (3,12) | 0,19 |
| ANT E′ VELOCITY (cm/sn) | 13,20 (3,87) | 14,53 (2,75) | |
| INF E′ VELOCITY (cm/sn) | 13,47 (3,77) | 14,38 (2,95) | 0,14 |
| SEP A′ VELOCITY (cm/sn) | 9,15 (2,28) | 8,59 (1,78) | 0,25 |
| LAT A′ VELOCITY (cm/sn) | 10,14 (2,74) | 9,72 (1,66) | 0,36 |
| ANT A′ VELOCITY (cm/sn) | 9,70 (2,94) | 9,17 (2,19) | 0,40 |
| INF A′ VELOCITY (cm/sn) | 9,92 (2,08) | 9,40 (1,34) | 0,14 |
| MEAN E′ VELOCITY (cm/sn) | 13,70 (3,39) | 14,45 (2,52) | 0,13 |
| MEAN A′ VELOCITY (cm/sn) | 9,63 (2,27) | 9,19 (1,35) | 0,22 |
| E′/A′ | 1,52 (0,58) | 1,60 (0,39) | 0,31 |
| E/E′ | 6,13 (1,12) | 6,2 (1,01) | 0,63 |
All results are expressed as mean values and numbers in brackets denote Standard Deviation.