Literature DB >> 21859593

In vitro identification of four-element windkessel models based on iterated unscented Kalman filter.

Huan Huang1, Ming Yang, Wangfu Zang, Shunjie Wu, Yafei Pang.   

Abstract

Mock circulatory loops (MCLs) have been widely used to test left ventricular assist devices. The hydraulic properties of the mock systemic arterial system are usually described by two alternative four-element windkessel (W4) models. Compared with three-element windkessel model, their parameters, especially the inertial term, are much more difficult to estimate. In this paper, an estimator based on the iterated unscented Kalman filter (IUKF) algorithm is proposed to identify model parameters. Identifiability of these parameters for different measurements is described. Performance of the estimator for different model structures is first evaluated using numerical simulation data contaminated with artificial noise. An MCL is developed to test the proposed algorithm. Parameter estimates for different models are compared with the calculated values derived from the mechanical and hydraulic properties of the MCL to validate model structures. In conclusion, the W4 model with an inertance and an aortic characteristic resistance arranged in series is proposed to represent the mock systemic arterial system. Once model structure is appropriately selected, IUKF can provide reasonable estimation accuracy in a limited time and may be helpful for future clinical applications.

Entities:  

Mesh:

Year:  2011        PMID: 21859593     DOI: 10.1109/TBME.2011.2161477

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

Review 1.  Lumped parameter model for hemodynamic simulation of congenital heart diseases.

Authors:  Shuji Shimizu; Dai Une; Toru Kawada; Yohsuke Hayama; Atsunori Kamiya; Toshiaki Shishido; Masaru Sugimachi
Journal:  J Physiol Sci       Date:  2017-12-21       Impact factor: 2.781

2.  Effects of Pulsatile Frequency of Left Ventricular Assist Device (LVAD) on Coronary Perfusion: A Numerical Simulation Study.

Authors:  Yuanfei Zhu; Ming Yang; Yan Zhang; Fan Meng; Tianyue Yang; Zhiwei Fang
Journal:  Med Sci Monit       Date:  2020-09-17

3.  Weaning from venous-arterial extracorporeal membrane oxygenation: The hemodynamic and clinical aspects of flow challenge test.

Authors:  Jing-Chao Luo; Yi-Jie Zhang; Jun-Yi Hou; Ming-Hao Luo; Kai Liu; Guo-Wei Tu; Zhe Luo
Journal:  Front Med (Lausanne)       Date:  2022-09-08
  3 in total